Checking and replacing the protective magnesium anode (if required)
F
Fig. 5
Returning the DHW cylinder to use
A
1x
C
D
Fig. 6
Check protective magnesium anode
If the protective magnesium anode has degraded to
7
1. Reconnect the DHW cylinder to the pipework.
2. Insert new gasket
3. Mount flange cover
4. Push earth cable
B
7x
5. Fill the DHW cylinder from the DHW side, then
E
6. Mount flange insulation
G
Commissioning, inspection, maintenance
10 to 15 mm, we recommend replacing it.
under flange cover
G
with earth cable
E
tighten the screws with a maximum torque of
25 Nm.
onto tab
C
tighten flange cover
with a torque of 25 Nm.
E
B
F
.
.
E
and
C
.
D
and cover
.
A