Installation sequence
Type WWKS: external heat generator
For connections to the DHW heat pump, see pages 9
and 21.
Fitting the temperature sensor
!
Please note
Damage to the connecting cables and sensor
leads (capillaries) causes malfunctions.
The connecting cables and sensor leads must
■
not come into contact with hot components.
When routing and securing connecting cables
and sensor leads, ensure that the maximum
permissible temperatures for these cables/
leads are not exceeded.
Never kink the capillary tubes.
■
2.
3.
4.
5.
Fig. 17
Adjusting the draw-off rate
If there is high demand for DHW, it is possible to
change the draw-off profile from L to XL. To do this, the
cylinder temperature sensor fitted at the factory is
removed from sensor well
.
B
Note
The high limit safety cut-out for the DHW heat pump
must also be refitted.
20
1.
A
and fitted in sensor well