Fitting the thermometer sensor (if available)
3. Route the thermometer sensor capillaries to the
back.
Note
Repeat the following steps for each of the thermom-
eters installed.
4. Depending on where the sensor is being fitted,
secure the thermometer sensor in the clamping
bracket or pull the sensor retainer out of the sensor
well.

Fitting the Vitotrans

Fig.3
2.
1.
(cont.)
5. Secure the sensor to the outside of the sensor
retainer contact spring so that it is flush with the
front of the spring.
Note
Never wrap insulating tape around the sensors.
Secure the sensor on the outside of the contact
spring of the sensor retainer (not in the groove)
so that it is flush with the front of the spring.
Insert the sensor retainer together with the sensor
into the sensor well as far as they will go.
6. Secure the thermometer sensor capillaries.
7. Insert the sensor retainer.
Installation sequence
9