Specifications - Omron D4BL Manual

Locking safety-door switch
Hide thumbs Also See for D4BL:
Table of Contents

Advertisement

D4BL
J OPERATION KEY (ORDER SEPARATELY)
Mounting type
Horizontal mounting
Vertical mounting
Adjustable mounting
(Horizontal)

Specifications

J APPROVED STANDARD RATINGS
TÜV (EN60947-5-1)
Item
Utilization category
Rated operating current (Ie)
Rated operating voltage (Ue)
As protection against short-circuiting, use either a gI-type or gG-type 10-A fuse (IEC269-approved).
UL/CSA (UL508, CSA C22.2 No. 14)
A300
Rated voltage
Carry current
y
120 VAC
10 A
240 VAC
Note: The UL/CSA approved rating for products with indicators (-A) is 6 A/115 VAC.
Part number
D4BL-K1
D4BL-K2
D4BL-K3
Standard model
Indicator model
AC-15
AC-15
3 A
6 A
250 V
115 V
Current
Make
60 A
30 A
Volt-amperes
Break
Make
6 A
7,200 VA
3 A
4
Break
720 VA

Advertisement

Table of Contents
loading