NOTE: Ignition module, valve, pilot and wall switch operate on 3 volts. 120 VAC is required at junction box.
Figure 25. Intermittent Pilot Ignition (IPI) Wiring Diagram
Step 8. Wiring the Fireplace
NOTE: Electrical wiring must be installed by a licensed
electrician.
CAUTION: DISCONNECT REMOTE CONTROLS IF AB-
SENT FOR EXTENDED TIME PERIODS. THIS WILL PRE-
VENT ACCIDENTAL FIREPLACE OPERATION.
Appliance Requirements
This appliance requires that 110-120 VAC be wired to the
factory installed junction box. Maintain correct polarity when
wiring the junction box. A wall switch is also required to
operate the unit . See wiring diagram for details.
CAUTION: AFTER WIRING THE APPLIANCE, YOU MUST
SILICONE THE HOLE IN THE FIBER BOX TO SEAL IT
FROM THE OUTSIDE. (HIGH TEMPERATURE 300 o F
OR 149 o C MINIMUM SEALANT.)
Optional Accessories
Optional remote control kits require that 110-120 VAC be
wired to the fireplace junction box.
Wall Switch
A wall switch is provided and is required. Position the remote
wall switch in the desired position on a wall. Run a maximum
of 25 feet (7.8 m) or less of 16 A.W.G. minimum wire with
male ends and connect it to the female ends .See wiring
diagram for details.
CAUTION: LABEL ALL WIRES PRIOR TO DISCONNEC-
TION WHEN SERVICING CONTROLS. WIRING ERRORS
CAN CAUSE IMPROPER AND DANGEROUS OPERATION.
VERIFY PROPER OPERATION AFTER SERVICING.
22