Installing Vent Components - Heat-N-Glo CFX-DA Installer's Manual

Table of Contents

Advertisement

B. Installing Vent Components
1. Attach the First Vent Component to the
Starting Collars
To attach the first vent component to the starting collars
of the fireplace:
• Apply a 3/8 inch (9.5mm) bead of stove cement around
the 5 inch (127mm) fireplace starting collar.
• Slide the first vent section onto the collars attached to
the top of the unit. Use four self tapping screws to se-
cure the outer pipe to the outer collar.
• When the internal beads of each pipe line up, rotate the
pipe section clockwise about one-quarter (1/4) turn. The
vent pipe is now locked together.
STARTING
COLLAR
FIRST VENT
COMPONENT
Figure 9. Attaching the First Vent Component
to the Starting Collars
WARNING: A 3/8 INCH (9.5 MM) BEAD OF
!
STOVE CEMENT MUST BE PLACED AROUND
THE 5 INCH (127 MM) FIREPLACE STARTING COL-
LAR BEFORE ATTACHING THE FIRST VENT COM-
PONENT. FAILURE TO SEAL THIS JOINT MAY
CAUSE THE FIREPLACE TO OPERATE IMPROPER-
LY. SEE THE DIAGRAM .
2. Continue Adding Vent Components
• Continue adding vent components, locking each succeed-
ing component into place.
• Ensure that each succeeding vent component is secure-
ly fitted and locked into the preceding component in the
vent system.
• 90° elbows may be installed and rotated to any point
around the preceding component's vertical axis. If an el-
bow does not end up in a locked position with the pre-
ceding component, attach with a minimum of two (2)
sheet metal screws.
3/8" (9.5mm)
STOVE
SEALANT
BEAD
1 INCH
(25.4mm)
15
Figure 10. Adding Venting Components
3. Install Support Brackets
For Horizontal Runs - The vent system must be supported
every five (5) feet of horizontal run by a horizontal pipe support.
To install support brackets for horizontal runs:
• Place the pipe supports around the vent pipe.
• Nail the pipe supports to the framing members.
For Vertical Runs - The vent system must be supported
every eight (8) feet (2.4m) above the fireplace flue outlet by
wall brackets.
To install support brackets for vertical runs:
• Attach wall brackets to the vent pipe and secure the wall
bracket to the framing members with nails or screws.
FLUE
OUTLET
1 INCH MIN.
(25.4mm)
Figure 11. Installing Support Brackets
WALL BRACKET
WALL STUD
8 FT. (2.4m)