Step 8 Wiring The Fireplace - Heat-N-Glo HV-CDN Installer's Manual

Table of Contents

Advertisement

THERMOCOUPLE
Figure 26. Standing Pilot Ignition Wiring Diagram
Step 8. Wiring the Fireplace
NOTE: Electrical wiring must be installed by a licensed
electrician.
CAUTION: DISCONNECT REMOTE CONTROLS IF AB-
SENT FOR EXTENDED TIME PERIODS. THIS WILL PRE-
VENT ACCIDENTAL FIREPLACE OPERATION.
For Standing Pilot Ignition Wiring
Appliance Requirements
• This appliance DOES NOT require 110-120 VAC to operate.
WARNING: DO NOT CONNECT 110-120 VAC
!
TO THE GAS CONTROL VALVE OR WALL
SWITCH OR THE APPLIANCE WILL MALFUNCTION
AND THE VALVE WILL BE DESTROYED.
BLK
BLK
TEMPERATURE
SENSOR SWITCH
JUNCTION BOX
Figure 27. Fan Wiring Diagram
GAS
VALVE
VARIABLE SPEED CONTROL
BLK
BLK
TEMPERATURE
SENSOR SWITCH
SPEED CONTROL
(RHEOSTAT)
THERMOPILE
RED T2
WHITE T1
Optional Accessories
Optional fan and remote control kits require that 110-120
VAC be wired to the factory junction box before the fire-
place is permanently installed.
Wall Switch
Position the wall switch in the desired position on a wall.
Run a maximum of 25 feet (7.8 m) or less length of 18
A.W.G. minimum wire and connect it to the fireplace ON/
OFF switch pigtails.
CAUTION: LABEL ALL WIRES PRIOR TO DISCONNEC-
TION WHEN SERVICING CONTROLS. WIRING ERRORS
CAN CAUSE IMPROPER AND DANGEROUS OPERATION.
VERIFY PROPER OPERATION AFTER SERVICING.
JUNCTION BOX
BLK
BLK
BLK
WHT
WHT
BLK
GROUND
GRN
BLK
WHT
110-120 VAC
NOTE: If any of the original wire as supplied
with the appliance must be replaced, it must
be replaced with type 105
25
WALL SWITCH OR
OPTIONAL REMOTE
BLOWER RECEPTACLE
BLOWER
O
C rated wire.

Advertisement