6.7.2 RFID Calibration Operation Example

NOTE: Be sure to complete the following before performing an RFID calibration.
1) Select a usable antenna position in the system mode. (Refer to Section 6.7.1 Outline of the
RFID Calibration.)
2) Place the RFID media at the print start position in advance by performing an automatic
calibration (<7>AUTO. CALIB.).
[Online mode]
1. Normal state
[Online mode]
2. Pause state
[RFID Calibration]
3.
Calibration start
[RFID Calibration]
4. Calibration is being
performed.
[RFID Calibration]
5a. Result: Detected.
[RFID Calibration]
5a.
Result: Not found.
(Supplementary Explanation)
(1) The position and AGC value obtained through an RFID calibration are calibrated with reference to
the media at the print start position.
(2) When the [ENTER] key is released within 3 seconds while the printer is paused, the [ENTER] key is
invalid.
(3) After performing an RFID calibration, the printer returns the RFID media to the print start position.
(4) An RFID calibration is enabled when the FORWARD WAIT parameter is set to ON. In this case, the
printer feeds the RFID media to the print start position temporarily, performs an RFID calibration,
then returns the media to the former position.
↓ Press [PAUSE] key.
↓ Hold down [ENTER] key for 3 seconds.
Press [CANCEL] key to
return to the normal
state.
↓ Press [ENTER] key.
Pressing the [ENTER] key returns the display to 1. Normal
state.
The value of "POSITION" is set for "CALIB. POSITION", the
value of "AGC" is set for "CALIB. AGC", and "CALIB. MODE"
is turned ON.
Pressing the [CANCEL] key returns the display to 1. Normal
state.
Values of "POSITION" and "AGC" on the display are not
saved.
Pressing the [CANCEL] key returns the display to 1.
No value is saved.