  • Page 1 SMART 2000 Digital Programmable Thermostat Owners Manual www.robertshaw.com 2/15 – 352-00194-001 ©2015 Robertshaw...
  • Page 2 IMPORTANT SAFETY INFORMATION WARNING: ELECTRICAL SHOCK HAZARD – Turn off power at the main power source by unscrewing fuse or switching circuit breaker to the OFF position before installing, removing, or cleaning this thermostat. WARNING: FIRE AND ELECTRIC SHOCK HAZARD – This device should be installed by a qualified service technician wit ue regard for safety as improper installation could result in a fire and...
  • Page 3: Table Of Contents

    TAbLE OF CONTENTS Introduction Programming the SMART 2000 Common Functions SMART 2000 Buttons Control Modes SMART 2000 Fan Functions Single Fan Speed Three Fan Speed SMART 2000 LCD Padlock Symbol Wrench Icon Satellite Symbol Locked Clean Filter RECO HOLD FAULT ModBus Communications Remote Temperature Sensors...
  • Page 4 Residential Programmable Mode On / Off and Mode Selection Setting the Fan Functions Setting the Clock Programming Your Four Daily Events To Enter The Program Mode To Set a Permanent Program Hold To Review the Set Temperature Commercial Programmable Mode On /Off and Mode Selection Setting the Fan Functions Setting the Clock Programming Your Two Daily Events To Enter the Program Mode After Hours Run Timer To Review the Set Temperature Manual Mode...
  • Page 5 Specifications Troubleshooting One Year Limited Warranty Thank you for purchasing a Uni-Line SMARTSENSE thermostat. The SMART 2000 ® is a multi-function thermostat. If properly installed your SMART 2000 thermostat will provide you with many years of trouble free comfort. The SMART 2000 has been built to be an attractive, highly reliable and an easy to use thermostat. By taking the time to read and understand these simple instructions you can take advantage of many of the capabilities that are offered in this premium product.
  • Page 6: Introduction

    INTRODuCTION The SMART 2000 thermostat is able to be used as a residential programmable thermostat, a commercial programmable thermostat or as a simple to use manual thermostat. Your installer has selected the mode to best suit your individual needs. You can check the SMART 2000 display to determine if your thermostat is: Programmable or Manual Commercial or Residential When power is turned on, the SMART 2000 will perform a short start-up and begin to operate. To determine if the thermostat is operating in Programmable Commercial or Programmable Residential mode, look at the top left display window. • If the word START or STOP is displayed, the mode is Programmable Commercial. • If a dark box with a number is displayed, the mode is Programmable Residential.
  • Page 7 To further determine if the Manual mode is Residential or Commercial, use the MODE button. • Press the MODE button until the left center window displays MODE and HEAT. • Press the p button to display SET and a temperature setting in the large window. • Press p again to raise the number by one degree. • Remember to record that new number.
  • Page 8: Programming The Smart 2000

    The SMART 2000 thermostat can be configured by your installer for a large variety of configurations and functions so that your thermostat is set to meet your individual needs. This manual may describe a function or feature not active on your thermostat. PROGRAMMING THE SMART 2000 This thermostat has several features and operating modes that the user should become familiar with before programming. The steps to properly program your SMART 2000 are: • Determine which type of thermostat (programmable or manual) you have. • Take the time to write down any temperature settings or start/stop times you will be using, Table 1 - Heating and Table 2 - Cooling.
  • Page 9 Table 1 Heating Schedule Program 1 Program 2 Program 3 Program 4 Monday Time Time Time Time Temp Temp Temp Temp Tuesday Time Time Time Time Temp Temp Temp Temp Wednesday Time Time Time Time Temp Temp Temp Temp Thursday Time Time Time...
  • Page 10 Table 2 Cooling Schedule Program 1 Program 2 Program 3 Program 4 Monday Time Time Time Time Temp Temp Temp Temp Tuesday Time Time Time Time Temp Temp Temp Temp Wednesday Time Time Time Time Temp Temp Temp Temp Thursday Time Time Time...
  • Page 11: Common Functions

    COMMON FuNCTIONS SMART 2000 buttons MODE Press this button to cycle the SMART 2000 thermostat through the available modes: Heat only, Cool only, Auto changeover mode, Emergency Heat (if fitted), and OFF. When setting the thermostat to OFF mode, the fan mode will change automatically to Fan Auto mode so the fan does not continue to run unexpectedly. NOTE: Not all modes may be active on your thermostat. O/RIDE (OvERRIDE) Commercial Programmable Mode This button initiates the after hours run timer. This is an installer programmed period which replaces the stop program temperatures and temporarily uses the start program temperatures for a pre-set 2-hour period. A second press will cancel the after hours run timer.
  • Page 12 UP (p) Use this button to increase the desired room temperature for the heating or cooling modes, or increase a “value” in programming modes. Also used to override the pre-programmed temperatures and temporarily replace them with a new higher set temperature for a 2-hour period. The user can change this override period to hold until the next scheduled event. DOwn () Use this button to decrease the desired room temperature for heating or cooling modes, or decrease a “value” in programming modes. Also used to override the pre-programmed temperatures and temporarily replace them with a new lower set temperature for a 2-hour period. The user can change this override period to hold until the next scheduled event.
  • Page 13: Control Modes

    Single Speed Fan Systems Press this button to cycle between Continuous Fan (Fan ON) and Auto Fan. Three Speed Fan Systems Press this button to cycle between the seven available fan modes: Low Speed, Medium Speed, High Speed and Auto Fan Speeds in Auto Fan mode and then Low Speed, Medium Speed, High Speed in Fan ON mode. If the SMART 2000 is OFF, pressing the FAN button will turn the fan ON or OFF as desired. If your system has three fan speeds these can also be selected by pressing the FAN button. CONTROL MODES Heat Only Mode The SMART 2000 thermostat will turn on the Heating when the room temperature falls below the Heat setpoint temperature. In Heat Only mode, the thermostat will NOT bring on the Cooling regardless of the room temperature and the Cooling setpoint temperature. In Heat Only mode, only the word HEAT will be displayed in the LCD.
  • Page 14 Emergency Heat Mode The SMART 2000 thermostat will only use your emergency heating device to maintain your desired heating temperature. This method of heating can be quite expensive therefore it is not recommended to use emergency heat mode unless it is essential. When your air conditioning system is heating using emergency heat, the word E.HEAT in the LCD will change to the word E.HEATING. Cool Only Mode The SMART 2000 thermostat will turn on Cooling when the room temperature rises above the Cool setpoint. In Cool Only mode, the thermostat will NOT turn on the Heating regardless of the room temperature and Heating setpoint temperature. In Cool Only mode, only the word COOL will be displayed in the LCD. When your air conditioning system is cooling, the word COOL in the LCD will change to the word COOLING. If the word COOL is flashing in the LCD the SMART 2000 is performing a safety anti-cycle delay prior to restarting the Cooling.
  • Page 15: Smart 2000 Fan Functions

    desired room temperature. Auto Changeover mode is indicated by both the words HEAT and COOL in the LCD. If the word HEAT or COOL is flashing in the LCD the SMART 2000 is performing a safety anti-cycle delay prior to restarting the air conditioning system. SMART 2000 Fan Functions Auto Fan Mode If Auto Fan mode with the FAN button is selected, the indoor fan will turn ON when the heating or cooling turns on, and OFF again once the heating or cooling turns off. To conserve energy, your fan may continue to run momentarily after the heating or cooling has stopped to extract all the warm or cool air still remaining in the air conditioning system and bring that conditioned air into the building. Fan On Mode Manual Thermostat Mode - Your fan will run continuously. Programmable Thermostat Mode - By selecting Fan On or Continuous Fan mode the thermostat indoor fan may operate continuously between the START or number 1 programs and the STOP or number 4 programs and then turn ON and OFF as required with heating and cooling outside of those programmed events.
  • Page 16: Single Fan Speed

    NOTE: Your installer may have activated some of the many advanced indoor fan management capabilities of the thermostat that work in partnership with the Fan On Mode. This may result in the fan operating differently than described above. If you find this to be the case and undesirable, please contact your authorized service agent for advice on altering the function.
  • Page 17 Figure 1 Figure 2 Pressing the FAN button will step the fan speed selection through LOW, then MED, then HIGH fan and Auto fan speed (indicated by all three fan speeds being shown on the LCD) in auto fan mode, the LOW, MED and HIGH in Fan On mode. If Auto Fan Speed has been selected, the thermostat will indicate the selected fan speed by flashing the appropriate word in the LCD. If Auto Fan Speed has been selected, your thermostat will automatically select the most appropriate fan speed based on the difference between the room and set temperatures.
  • Page 18: Smart 2000 Lcd

    SMART 2000 LCD Figure 3 NOTE: Your thermostat is capable of many advanced control capabilities designed to both save energy and improve comfort levels. If any part of the display is flashing during normal use, a safety, energy management or program delay/override is in progress. Padlock Symbol Whenever this symbol is shown, a control limit has been reached and a button or a function has been locked out.
  • Page 19: Wrench Icon

    Wrench Icon If you see a wrench symbol flashing on your LCD, the installer has left your thermostat in Commissioning Mode. Although your thermostat will operate your heating and cooling system while in Commissioning Mode, all active safety and energy conservation delays have been disabled. It is therefore HIGHLY recommended that you contact your installer and request that the Commissioning Mode be disabled. Satellite Symbol This indicates that your thermostat is receiving information from a building management system (or BMS). The information received from the BMS may change the function (mode or set temperature) of the thermostat. Locked The temperature of the outside air can initiate or prevent certain functions within the thermostat control logic. If such a function has been prevented based on the outside air temperature, the word LOCKED appears. These functions will automatically unlock once the outside air temperature becomes favorable.
  • Page 20: Clean Filter

    Clean Filter This is a reminder to you to clean or replace your return air filter. Once you have cleaned or replaced your return air filter, PRESS and HOLD both the MODE and FAN buttons together for 5 seconds. The LCD will blink, the filter counter will reset and the text CLEAN FILTER will vanish. RECO If the Adaptive Recovery mode is active, the thermostat will pre-warm or pre-cool your building to ensure your set temperatures are reached by your scheduled event start time. Whenever the thermostat is performing a pre-warming or cooling, the word RECO (recovery) will be shown on the LCD. HOLD This indicates that the residential program is ON HOLD (inactive) and a permanent set temperature is being used. This temperature can be changed manually if desired. Automatic time-based temperature changes are suspended.
  • Page 21: Modbus Communications

    Modbus Communications Your thermostat has circuitry which permits it to receive commands or provide data to a building management system. A satellite symbol will be displayed on the LCD when this communication is in progress. The intent of these communications is to permit the centralized control of all building functions which can include building climate control. All thermostat user and installer functions can be accessed via the BMS and overrides may be made to any setting made by the user. This ability is especially useful when a large building with multiple air conditioning units must be controlled. Remote Temperature Sensors Your thermostat is fitted with an accurate and reliable internal temperature sensor used to measure the room temperature.
  • Page 22: Residential Programmable Mode

    RESIDENTIAL PROGRAMMAbLE MODE On / Off and Mode Selection Press the Mode button to cycle the thermostat through the available modes, HEAT, COOL, AUTO Mode (Shown by HEAT and COOL in the LCD), EMERGENCY HEAT (if fitted), and OFF. If the Fan mode is set to FAN ON, when you select OFF mode the Fan mode will automatically change to FAN AUTO. NOTE: Not all modes may be active on your thermostat. Mode Cool Heat ON-Auto Setting the Fan Functions Detail on the fan control functions of the SMART 2000 can be found on page 15 of this manual.
  • Page 23: Setting The Clock

    Setting the Clock The thermostat is fitted with a real time clock. This clock is used by the thermostat for the programming functions as described below. It is essential that the clock time and day are set accurately for programmed events to start on time.   To set the clock, press the PROG button. The LCD will show the Hours Digits flashing. Use the p or  buttons to adjust the hours to the correct time (note the AM / PM symbol). Press the PROG button again and the Minutes digits will flash. Adjust this value using the p or  buttons to show the correct minute. Press the PROG button again and the weekday flashes, again use the p or  buttons to set this value to the correct day of the week. Press the PROG button again to exit the clock set function. Programming Your Four Daily Events The SMART 2000 is a 7-day programmable thermostat. For each day of the week, you can schedule four timed set temperature changes or programmed events. For clarity, these events are conveniently named 1, 2, 3 and 4.
  • Page 24 The number 3 event is often used to set the temperature you wish to be greeted with upon returning home at the end of the day. The number 4 events can be used to set a comfortable and energy efficient temperature while you sleep.   You can schedule every event to occur at a different time of the day and set a different heating and cooling temperature for each of the 4 daily events. Also, you can set a heating setpoint temperature between the Heating turned OFF (no heating) and 113ºF (45ºC). You can set a cooling temperature between 109ºF (43ºC) and the Cooling OFF (no Cooling), provided your installer has not set control limits that restrict this range of adjustment. Remember, each of the four programmed event desired temperatures will hold the home temperature until the next event time arrives. Then the new event set temperature will then be used. • The 1 event set temperature will be the temperature of your home until the 2 event time arrives, then • The 2 event set temperature will be the temperature of your home until the...
  • Page 25: To Enter The Program Mode

    Use Tables 1 and 2 on pages 9 and 10 to record your events. Programming your thermostat or setting these daily events is similar to setting the clock as described previously. The same buttons are used in the same sequence, using the PROG button to advance to the next step, and the p or  buttons to make changes. The LCD shows only relevant information for the event being adjusted. This reduces possible errors that may be caused by having confusing information displayed on the LCD. To Enter The Program Mode Press and hold the PROG button for three seconds. The display will change to show the number 1 and the Day Monday flashing. Using the p or  buttons, adjust the day to the day you wish to start programming or to the day you wish to edit an existing event or program.
  • Page 26 Press the PROG button to advance to the next step. The LCD will show the digit 1 with the hour’s digit flashing. Using the p or  buttons, adjust the hours to the time you wish the number 1 event to commence for the currently selected day. Press the PROG button again, now the Minutes digits flash. Using the p or  buttons, set the minute to the time you wish the number 1 event to begin. Press the PROG button again, now the word HEAT (if enabled by the installer) and a temperature value is shown in the LCD. Use the p or  buttons to set the desired heating temperature to be maintained for the number 1 event. Figure 6 Press the PROG button again, now the word COOL (if enabled by the installer) and a temperature value is shown in the LCD. Use the p or  buttons to set the desired cooling temperature to be maintained for the number 1 event.
  • Page 27 Press the PROG button again and the Day previously selected will be shown along with the digit 2, signifying the 2nd daily event is now being programmed. The Hour digit will flash indicating that this value can now be adjusted with the p or  buttons. Set the hour to the time you wish the number 2 event to begin as described previously. Continue to press the PROG button to advance through the number 2 Minute, then the set temperature(s) for the number 2 event. Continue to press the PROG button. You will advance to the number 3 program and then number 4 programs for the day you have chosen to program. Once you have completed programming the number 4 event for that day, press the PROG button again and the LCD will show the word COPY. You now have TwO options: Option 1 –...
  • Page 28 PROG button to initiate the copy process. The word COPY will flash briefly to confirm the copy process and your current days values will be copied to the days selected. Normal programming steps will resume at the next day to be programmed. Figure 7 Figure 8 Temperature Override The SMART 2000 has a temporary program override function. This permits you to temporarily change the current event set temperatures, for a temporary period. Your installer has selected either a fixed timed override period from 1 to 12 hours, or an override that lasts until the next programmed event change. To use this feature press and hold the p or  buttons for three seconds. The SMART 2000 thermostat display will change to show the word SET, and the active setpoint for the current mode (Heating, Cooling or Auto modes), Figure 8. As you hold the p or  buttons, the current setpoint will change.
  • Page 29: To Set A Permanent Program Hold

    If Auto mode is selected, after adjusting the Heat setpoint, wait without touching a button for three seconds for the thermostat display to change to show COOL and SET and your current cooling set temperature. If desired, change this value with the p or  buttons. Again, wait for three seconds to exit the temporary overridden programmed mode. The LCD will flash the current Program indicator to remind you an override is in progress. Your new temporary temperature settings will be in use until the override time expires. To Set a Permanent Program Hold Press the O/RIDE button to override the thermostat programmed time schedule and hold the currently set temperature. This set temperature will be maintained until released by pressing the O/RIDE button again. The LCD shows the word HOLD to confirm the time schedule has been overridden and the current selected temperature is being held, Figure 9. Figure 9...
  • Page 30: To Review The Set Temperature

    If desired, while the program is held, the current set temperature can be adjusted by pressing and holding the p or  buttons for three seconds. The thermostat display will change to show the word SET, and the active setpoint for the current mode (Heating or Cooling). As you hold the p or  buttons, the current setpoint will change. To Review the Set Temperature Press the p or  buttons to first turn the LCD backlight ON, then press again to display the currently set temperature(s). COMMERCIAL PROGRAMMAbLE MODE On /Off and Mode Selection Press the Mode button to cycle the thermostat through the available modes,...
  • Page 31: Setting The Clock

    Setting the Clock The thermostat is fitted with a real time clock. This clock is used by the thermostat for the programming functions as described below. It is essential that the clock time and day are set accurately for programmed events to start on time.   To set the clock, press the PROG button. The LCD will show the Hours Digit flashing. Use the p or  buttons to adjust the hours to the correct time (note the AM / PM symbol). Press the PROG button again and now the Minutes digit will flash. Adjust this value using the p or  buttons to show the correct minute. Press the PROG button again and now the weekday flashes, again use the p or  buttons to set this value to the correct day of the week. Press the PROG button again to exit the clock set function. Programming Your Two Daily Events Commercial programming of the SMART 2000 has been designed to be a simple and logical process. The thermostat permits you to program a Start time for the air conditioning system, then a Stop time for each day of the week. When the thermostat is displaying START in the LCD, it will maintain whatever setpoint...
  • Page 32: To Enter The Program Mode

    To Enter the Program Mode Figure 10 Figure 11 Press and hold the PROG button for three seconds. The display will change to show the Day Monday flashing. Use the p or  buttons to set the day you wish to start programming an event or to the day you wish to edit an existing event. Press the PROG button to advance to the next step. The LCD will show the word START with the Hours digit flashing, Figure 12. Use the p or  buttons to adjust the hours value to the time you wish the building air conditioning system to start.
  • Page 33 Figure 12 Figure 13 Press the PROG button again, now the Minute digits flashes. Use the p or  buttons to set the minutes to the time you wish the building air conditioning system to START for the currently selected day. Press the PROG button to advance to the next step. The LCD will show the word STOP with the hours digit flashing. Use the p or  buttons to adjust the hours to the time you wish the building air conditioning system to STOP for the currently selected day. Press the PROG button again. Now the Minute digits flash. Use the p or  buttons to set the minutes to the time you wish the building air conditioning system to STOP for the currently selected day. The LCD will now show the word COPY.
  • Page 34 You now have TwO options: Option 1 - Continue programming as above Continue to press the PROG button to advance to the next day. Enter START and then STOP times and then advance to the next day. Option 2 - Copy Program To copy the values you have just set to other days of the week, press the p or  buttons to TAG each additional day you wish to copy the currently set days program to. When you have finished Tagging the days you desire, press the PROG button to initiate the copy process. The word COPY will flash briefly to confirm the copy process, Figure 13, and your current days values will be copied to the days selected. Normal programming will resume at the next day to be programmed. NOTE: Your thermostat's programs may be controlled from a BMS, thereby overriding any program you may have entered into the...
  • Page 35: After Hours Run Timer

    After Hours Run Timer For convenience, the installer may have set the after hours run function. This function permits you to temporarily turn the SMART 2000 ON for an installer pre- set period of time if the STOP program is running. At the conclusion of that time period, the thermostat will automatically turn back OFF again. Figure 14 To activate the after hours run timer, press the O/RIDE button (or the optional AFTER HOURS run button on the remote room temperature sensor). The LCD will show the word OVERRIDE flashing in the LCD. You can cancel any unexpired portion of the timer period by pressing the O/RIDE button again. The word OVERRIDE will vanish from the screen. To Review the Set Temperature Press the p or  buttons to first turn ON the LCD backlight, then press again to display the currently set temperature(s).
  • Page 36: Manual Mode

    MANuAL MODE On / Off and Mode Selection Press the Mode button to cycle the thermostat through the available modes: Heat, Cool, Auto mode (Shown by HEAT and COOL in the LCD), Emergency Heat (if fitted), and OFF. If the Fan mode is set to FAN ON, when you select OFF mode the Fan mode will automatically change to FAN AUTO. NOTE: Not all modes may be active on your thermostat. Setting the Fan Function Details on the fan control functions of the thermostat can be found on page 15 of this manual. Setting the Clock The thermostat is fitted with a real time clock. This clock is provided to display the current time. It has no other function. To set the clock, press and hold the PROG button for three seconds. The LCD will show the Hours Digit flashing. Use the p or  buttons to adjust the hours to the correct time (note the AM / PM symbol). Press the PROG button and now the Minutes digits will flash. Adjust this value using the p or ...
  • Page 37: Setting Your Desired Temperature

    Press the PROG button again and now the week day flashes. Use the p or  buttons to set this value to the correct day of the week. Press the PROG button again to exit the clock set function or wait 30 seconds for the thermostat to auto exit this menu. Your clock is now set. Setting Your Desired Temperature Press and hold the p or  buttons for three seconds. The thermostat display will change to show the word SET, and the active setpoint for the current mode (Heating or Cooling). As you hold the p or  buttons, the current setpoint will change. If Auto mode is selected (shown by both HEAT and COOL on the display) after adjusting the Heat setpoint, wait without touching a button for three seconds. The thermostat display will change to show COOL and SET and your current cooling set...
  • Page 38: To Review The Set Temperature

    Press the PROG button to switch between Day and Night Modes. Set the Day and separate Night temperatures as described previously. To Review the Set Temperature Press the p or  buttons to first turn the LCD backlight, then press again to display the currently set temperature(s). SPECIFICATIONS Input Voltage 24V AC 50/60 Hz +/- 15% Relay Rating 24V AC @ 1 Amp maximum per relay Operating Temperature 32 to 122ºF (0 to 50ºC) Operating RH 0 - 95% (non condensing) Storage Temperature 32 to 150ºF (0 to 65ºC)
  • Page 39 Timed Upstage Delay 5 - 90 minutes Anti-Cycle Delay Off to 4 minutes Maximum Hourly Cycles Unlimited, 30, 10 or 6 (Installer set) 1 ºF degree (0.5 ºC degrees) Display Resolution Control Range OFF to 100ºF (38ºC) Outside Air Temp Display Range 17 to 140ºF (-8 to +60ºC) Backlight Blue Backlight Life 3,000 hours to half brightness Adaptive Recovery Method Time to start vs temp differential method - updating Communications Protocol ModBus – contact Robertshaw for objects list Fan Speeds Based on difference between room and set temperature Approvals FCC (Part 15) (pending), C-tick...
  • Page 40 Warranty One year warranty TROubLESHOOTING Symptom Problem Solution Temperature Air from the wall cavity may Plug holes in wall with tape to display seems be leaking into the rear of the prevent leaks. inaccurate. thermostat / sensor enclosure. External heat or cool source such Move lamps, vents or as lamps, televisions or drafts other sources of abnormal...
  • Page 41 Symptom Problem Solution LOCKED appears This is not a fault. Heating and/or cooling disabled on LCD and to conserve energy. The heating Outside air temperature too high heating or cooling or cooling function can be to require heating. will not operate. disabled when the outside Outside air temperature too low temperature is warm or cool to require cooling. enough to not warrant the use of the A/C system.
  • Page 42 Symptom Problem Solution Heating, Heating and or cooling Set a lower heat temperature Cooling or Air temperatures set for and/or a higher cooling Conditioning unachievable value. temperature. Review manual on System seems to setting temperatures. runs all night. Heat Cool System set to Heat Installer setting incorrect – call Pump Mode.
  • Page 43 Symptom Problem Solution Cannot enter SMART 2000 thermostat set for Heating or cooling mode is not heat or cool Heating or Cooling only modes. available on your system. modes. Cannot set This is not a fault. Contact your installer and heating and request these limits to be Your installer has set control cooling to desired removed / adjusted.
  • Page 44 Symptom Problem Solution HEAT or COOL is This is not a fault. Heating or The thermostat is performing an flashing in the cooling will start shortly. anti-cycle time delay to conserve LCD. Heating or energy and to protect the cooling has not heating, cooling or A/C system. started. Contact the installer if you wish this function disabled (NOT recommended). The Fan runs on This is not a fault.
  • Page 45 ONE YEAR LIMITED WARRANTY Robertshaw warrants to the original contract installer, or to the original consumer user, that each new Robertshaw thermostat will be free of defects in materials and workmanship under normal use and service for a period of one (1) year from the date of purchase (the “Warranty Period”). If any Product fails within the applicable Warranty Period, Robertshaw shall, at its option, repair or replace the Product or credit the purchase price, provided the Product is returned to Robertshaw’s facility or designated agent with transportation charges prepaid, and the Product, upon examination by Robertshaw, is found not to conform to the Warranty. Cost of Product removal, labor, or reinstallation of new Product are not covered...
  • Page 46 TORT, NEGLIGENCE, STRICT LIABILITY, INDEMNITY, PRODUCT LIABILITY, OR OTHERWISE, AND EVEN IF ROBERTSHAW HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. REPAIR, REPLACEMENT OR CREDIT OF THE PURCHASE PRICE SHALL CONSTITUTE THE SOLE REMEDIES WITH RESPECT TO DEFECTS IN THE PRODUCTS. THE CONSUMER ASSUMES ALL RISKS AND LIABILITY FOR INCIDENTAL AND CONSEQUENTIAL DAMAGE RESULTING FROM INSTALLATION AND USE OF THE THERMOSTAT. Some states does not allow the exclusion or limitation of incidental or consequential damages, or allow limitations on how long an implied warranty lasts, so the above limitations or exclusions may not apply to you. This Warranty gives you specific legal rights, and you may also have other rights which vary from state to state. Return for Warranty Consideration 1. All Products to be considered for warranty must be returned to Company with shipping charges prepaid.
  • Page 48 Robertshaw®, Uni-Line® and SmartSense are trademarks of Robertshaw, its subsidiaries and/or affiliated companies. All other brands mentioned may be the trademarks of their respective owners. Customer Service Telephone 1.800.304.6563 Customer Service Facsimile 1.800.426.0804 HVACCustomerService@robertshaw.com For Technical Service www.uni-line.com www.robertshaw.com Telephone 1.800.445.8299 ©2015 Robertshaw Facsimile 1.630.260.7294 2/15 – 352-00194-001 TechnicalService@robertshaw.com...