Selecting a Charge Profile

Selecting a Cha rge Profile
Electrocution/burn hazard.
Contact with electrically charged
circuits could result in death or
serious injury. Remove all rings,
watches and other jewelry.
1
At the ground controls, turn the key switch to
the off position and push in the red
Emergency Stop button to the off position.
2
Open the battery compartment.
3
Press and hold the charge profile selection
button and plug the battery charger into an
AC power source. Continue to hold the button
until the amber error indicator is on and the
green charging indicator light is flashing.
Release the button.
4
Press and release the charge profile selection
button to navigate to the charge profile
appropriate for your machine and battery
type. Refer to the chart below.
Profile
Description
P001
Flooded lead acid batteries - Temperature
compensated *
P003
Flooded lead acid batteries -
Not temperature compensated **
P007
Flooded lead acid batteries -
Not temperature compensated **
P043
AGM batteries -
Temperature compensated *
* Temperature compensated: Battery temperature
sensor has been installed on the machine.
** Not temperature compensated: Battery
temperature sensor has not been installed on the
machine.
Part No. 1314708GT
5
Press and hold the charge profile selection
button until the error indicator and charging
indicator lights turn off and the AC status
indicator light turns on to confirm selection
and exit charge profile mode. Release the
button.
Note: Charge profile mode will time out and exit if
there is 15 seconds of inactivity, the charge profile
number has been displayed three times or the AC
power source had been disconnected.
6
Press and release the charge profile selection
button to confirm the correct charge profile
has been selected.
GRC