10 Technical Data; Piping Diagram: Indoor Unit - Daikin Altherma 3 R W Installation Manual

Hide thumbs Also See for Altherma 3 R W:
Table of Contents

Advertisement

10 Technical data

10
Technical data
A subset of the latest technical data is available on the regional Daikin website (publicly accessible). The full set of latest technical data is
available on the Daikin Business Portal (authentication required).
10.1

Piping diagram: Indoor unit

A
C
R2T
a2
e
C
R4T
a1
e
A
Water side
B
Refrigerant side
C
Field installed
a1
Space heating/cooling – Water IN (screw connection, 1")
a2
Space heating/cooling – Water OUT (screw connection, 1")
b1
Gas refrigerant IN (heating mode; condenser)
b2
Liquid refrigerant OUT (heating mode; condenser)
c1
Liquid refrigerant IN (cooling mode; evaporator)
c2
Gas refrigerant OUT (cooling mode; evaporator)
d
Plate heat exchanger
e
Shut-off valve for service
f
Expansion vessel
g
Magnetic filter/dirt separator
h
Safety valve
i
Automatic air purge
j
Drain valve
k
Backup heater
l
Pump
Installation manual
40
EBBH*
B1PW
l
B1PW
EBBX*
j
h
f
i
g
j
B
i
R1T
k
B2L
B1PW
Space heating water pressure sensor
B2L
Flow sensor
Thermistors:
R1T
Heat exchanger – Water OUT
R2T
Backup heater – Water OUT
R3T
Liquid refrigerant
R4T
Heat exchanger – Water IN
Connections:
Screw connection
Flare connection
Quick coupling
Brazed connection
c2
b1
d
b2
R3T
c1
3D113750
EBBH/X11+16DF
Daikin Altherma 3 R W
4P643600-1B – 2021.10

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents