10 Technical Data; Piping Diagram: Indoor Unit - Daikin Altherma 3 R F Installation Manual

Hide thumbs Also See for Altherma 3 R F:
Table of Contents

Advertisement

10 Technical data

10
Technical data
A subset of the latest technical data is available on the regional Daikin website (publicly accessible). The full set of latest technical data is
available on the Daikin Business Portal (authentication required).
10.1

Piping diagram: Indoor unit

A
C
a2
g
b2
c
b1
C
a1
g
A
Water side
B
Refrigerant side
C
Field installed (delivered with the unit)
a1
Space heating/cooling – Water IN (screw connection, 1")
a2
Space heating/cooling – Water OUT (screw connection, 1")
b1
DHW – Cold water IN (screw connection, 3/4")
b2
DHW – Hot water OUT (screw connection, 3/4")
c
Recirculation connection
d1
Gas refrigerant IN (heating mode; condenser)
d2
Liquid refrigerant OUT (heating mode; condenser)
e1
Liquid refrigerant IN (cooling mode; evaporator)
e2
Gas refrigerant OUT (cooling mode; evaporator)
f
Plate heat exchanger
g
Shut-off valve for service
h
Flexible pipe
i
Expansion vessel
j
Magnetic filter/dirt separator
k
Safety valve
l
Automatic air purge
m
Drain valve
n
Pump
o
Backup heater
Installation manual
40
l
R2T
m
o
M3S
R8T
R5T
i
h
B1PW
B2L
R1T
k
l
R4T
n
j
m
B2L
Flow sensor
B1PW
Space heating water pressure sensor
M3S
3-way valve (space heating/domestic hot water)
Thermistors:
R1T
Outlet water heat exchanger
R2T
Outlet water backup heater
R3T
Refrigerant liquid side
R4T
Inlet water
R5T, R8T
Tank
Connections:
Screw connection
Flare connection
Quick coupling
Brazed connection
B
e2
d1
f
d2
R3T
e1
3D128638
EBVH/X11+16S18+23DJ
Daikin Altherma 3 R F
4P643599-1B – 2021.10