Installation Information - Viessmann VITOSOL F Installation Instructions Manual

Flat-plate collector for elevated installation
Table of Contents

Advertisement

Calculating collector row clearance z
Angle of inclina-
Collector row clearance z in mm
tion
α
Type SV
Flensburg
30°
45°
60°
Kassel
30°
45°
60°

Installation information

Align the collector array to face due south, or as
close to due south as possible.
Observe the maximum load and distance from the
edge of the roof for the on-site substructure to
DIN 1055.
Installation on concrete slabs
Remove any gravel or similar from the installation
area, cover the surface with protective building mats
and position support slabs on top of these mats.
Installation on steel beams
Install the on-site substructure at right angles to and
horizontally level with the collector orientation.
The Viessmann "SOLSTAT" calculation program is
available at www.viessmann.com to assist with bal-
last calculations.
8
(cont.)
Type SH
7630
5715
9600
4260
10,890
4830
6385
2845
7840
3480
8720
3870
, see fig. 4:
A
, see fig. 4:
B
Angle of inclina-
Collector row clearance z in mm
tion
α
Type SV
Munich
30°
45°
60°
Type SH
5595
2485
6710
2980
7350
3260