Fireplace Installation

Wiring

Hardwire Installation

The fireplace is packaged with a
two prong plug installed for plug-
in convenience. Hard wiring the
fireplace is also an option for any
installation.
WARNING: Do not attempt to
wire your own new outlets or
circuits. To reduce the risk of
fire, electric shock or injury to
persons, always use a licensed
electrician.
WARNING: Ensure that the
On/Off Switch is set to the Off
position (refer to Operation
section) and that the circuit
on which the fireplace is to be
installed has the power cut
off at the service panel until
installation is complete.
1. Remove the partially reflective
glass from the fireplace:
• Lay fireplace on its back.
M
M
RL3
RL2
RL1
• Remove two Phillips screws
from each of the two glass
brackets (Figure 2).
• Remove glass brackets.
• With one hand keeping
pressure on the partially
reflective glass, tilt the
fireplace upright and slightly
forward to allow the partially
reflective glass to fall out of
the inside framing.
Figure 2
Glass Bracket
L1
120V~
60Hz
N
N
N
N
Bracket Screws
Partially
Reflective Glass
9