Exmark LZS850EKA724W0 User Manual page 14

Table of Contents

Advertisement

1. Hydraulic trans oil
2. Use Exmark Premium Oil
service interval?
5.3.3 Access Historical Error Log
The historical error log displays errors that are no
longer active. The log keeps a running count of the
number of times the error has occurred during the life
of the machine and the non-resettable engine hour at
which the last occurred. The log displays the errors
starting with the most recent occurrence.
1. Historical error
2. Current error (e.g. Low oil
pressure)
5.3.4 Activate/Deactivate The Alarm Output
For Individual Errors
The alarms screen allows users to activate and
deactivate the audible alarm for individual errors.
Pressing the enter button brings the user to screens
that allows the user to activate or deactivate the
audible alarm for individual errors.
Note:
Not all audible alarms can be deactivated.
Figure 30
3. Y (yes)
4. N (no)
Figure 31
3. Number of times error
occurred during life of
machine (e.g. 3X)
4. Hour occurred
g030223
1. Alarms
2. Activate/Deactivate
The highlighted error name indicates that the audible
alarm is active. Pressing enter modifies the status of
the audible alarm to ON or OFF.
1. Alarms
2. Clutch overcurrent
3. Fuel low
The audible warning for the following errors can be
deactivated:
g030224
Service Engine Oil
Service Transmission Oil
Fuel Low
Clutch Overcurrent
Clutch Reset Required
Engine Error Codes
System Overvoltage>16VDC
System Undervoltage<9VDC
System Voltage Low
5.3.5 Adjust the Engine Speed Set Points
The screen allows the user to adjust the engine
speed at the Max, Efficient, and Low set points for
both transport (clutch disengaged) and mow (clutch
engaged) modes in 50 RPM increments.
14
Figure 32
3. Audible alert
4. Enter/Return
Figure 33
4. Toggle
5. Enter/Return
g030225
g038366