Spark Module / Transformer Removal:
1. Ensure all power,
gas and
grounding screws
are removed.
2. The spark module
is attached to the
PCB casing.
3. To remove, release the
two tabs securing the
module sub PCB to the
plastic casing and
disconnect the wire
connectors.
4. To remove the
transformer, remove the
single screw securing
transformer to the frame (A
tab fitted into slot secures
the rear of transformer)
and disconnect the wiring
from the PCB.