Rinnai EX08CT Installation And Operation Manual

Rinnai EX08CT Installation And Operation Manual

Direct vent wall furnace
Table of Contents

Advertisement

Available languages

Available languages

EX08CT............... (RHFE-202FTA2)
EX11CT ............... (RHFE-265FTA2)
Installer: Leave this manual with the appliance.
Consumer: Retain this manual for future reference.
READ ALL OF THE INSTRUCTIONS THOROUGHLY BEFORE INSTALLING OR OPERATING
THIS HEATER.
This manual provides information on the installation, operation, and maintenance of the heater. For
proper operation and safety, it is important to follow the instructions and adhere to the safety
precautions.
A licensed professional must install the fan convection heater according to the exact instructions
within this manual.
The consumer must read the entire manual to properly operate the heater and to have regular
maintenance performed.
WARNING
— Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other
appliance.
— WHAT TO DO IF YOU SMELL GAS
• Do not try to light any appliance.
• Do not touch any electrical switch; do not use any phone in your building.
• Immediately call your gas supplier from a neighbor's phone. Follow the gas supplier's instructions.
• If you cannot reach your gas supplier, call the fire department.
— Installation and service must be performed by a licensed professional.
Register your product at www.rinnairegistration.com or call 1-866-RINNAI1 (746-6241)
Installation and Operation Manual
If the information in these instructions is not followed exactly, a fire or explosion
may result causing property damage, personal injury or death.
Direct Vent Wall Furnace

Advertisement

Table of Contents
loading

Summary of Contents for Rinnai EX08CT

  • Page 1 Direct Vent Wall Furnace Installation and Operation Manual EX08CT....(RHFE-202FTA2) EX11CT ....(RHFE-265FTA2) Installer: Leave this manual with the appliance. Consumer: Retain this manual for future reference. READ ALL OF THE INSTRUCTIONS THOROUGHLY BEFORE INSTALLING OR OPERATING THIS HEATER. This manual provides information on the installation, operation, and maintenance of the heater. For proper operation and safety, it is important to follow the instructions and adhere to the safety precautions.
  • Page 2: Table Of Contents

    We will however, continue to contact you with information relevant to the product(s) you registered and/or your account with us. If you have any questions or feel that the manual is incomplete contact Rinnai at 1-800-621-9419 Important Safety Information Safety Definitions This is the safety alert symbol.
  • Page 3: Safety Behaviors And Practices For The Consumer And Installer

    This product can expose you to chemicals including Di (2-ethylhexyl) phthalate (DEHP) and carbon bisulfide which are known to the State of California to cause cancer, birth defects or other reproductive harm. For more information, visit www.P65Warnings.ca.gov. Rinnai Corporation EX08CT, EX11CT Manual...
  • Page 4: Installation Instructions (For The Licensed Professional) State Regulations

    Installation Instructions (for the licensed professional) State Regulations NOTICE BEFORE INSTALLATION: Rinnai direct-vent appliance must be installed by a state qualified or licensed contractor and a properly trained Rinnai Installer. If you are not properly trained, you must not install this unit.
  • Page 5: Included Installation And Vent Components

    9 1/2 - 15 3/4 in (240 - 400mm) C Vent Kit FOT-153 15 3/4 - 23 5/8 in (400 - 600 mm) D Vent Kit FOT-154 23 5/8 - 31 1/2 in (600 - 800 mm) Rinnai Corporation EX08CT, EX11CT Manual...
  • Page 6: Installation Instructions

    Care and Maintenance for adequate combustion carpets containing dyes or vinyl surfaces. and ventilation air. • Rinnai suggests that a dedicated electrical circuit with a 120VAC, 60 Hz, 10 amp power source be used. Rinnai Corporation EX08CT, EX11CT Manual...
  • Page 7: Prepare For Installation

    Materials that may be needed • Heat tape • Pipe insulation • Concrete wall anchors • Optional pipe cover • Optional temperature controller • 2 conductor 22 AWG wire for controller • Single gang electrical • Wire nuts Rinnai Corporation EX08CT, EX11CT Manual...
  • Page 8: Flue Terminal Clearances

    Clearance above grade, veranda, porch, deck, or balcony 12 inches (30 cm) 12 inches (30 cm) EX08CT - 6 inches (15 cm) EX08CT - 6 inches (15 cm) Clearance to window or door that may be opened EX11CT - 9 inches (23 cm)
  • Page 9: Clearances To Combustibles

    CFR, Part 3280 and/or CAN/SCA Z240 MH Practices section. Series, Mobile Homes. □ Rinnai recommends 10” (254 mm) clearance from the Leave the entire manual with the consumer. top and on both sides for servicing. 0” (0 mm) 0” (0 mm)
  • Page 10: Drilling Flue Hole

    • This appliance can only be used with one of the not exhaust into other rooms. five types of Rinnai flue kits. The flue kits and their dimensions are listed in the Specifications section. • The flue manifold is not designed to be positioned •...
  • Page 11 Push the assembly into the terminal tube, ensuring that the seal is in place on the inner tube. Attach the inside connection with 3 screws. The inner connection can still be turned to install the screws. 3 screws Rinnai Corporation EX08CT, EX11CT Manual...
  • Page 12: Extension Kit Installation

    Extension to the left (facing appliance) EXHAUST LONG BENT ELBOW PIPE LONG PIPE STOPPER A BENT ELBOW EXHAUST PIPE PIPE CLAMP EXHAUST ELBOW PIPE CLAMP PIPE CLAMP STOPPER A EXHAUST ELBOW INTAKE HOSE INTAKE CLAMP HOSE Rinnai Corporation EX08CT, EX11CT Manual...
  • Page 13 Hose joint another air intake hose into the hose joint. Do not cut the intake hose. Cutting NOTICE Air intake hoses the intake hose may result in noise. Rinnai Corporation EX08CT, EX11CT Manual...
  • Page 14 Hose Joint - 1.5 in (38 mm) inner dia. Hose Joint - 2.0 in (50 mm) inner dia. Pipe Stopper A Pipe Stopper B Pipe Clamp 2 sets 3 sets 4 sets Wall Fixture Screw A Screw B Rinnai Corporation EX08CT, EX11CT Manual...
  • Page 15: Connecting The Appliance

    6. Install the wall bracket with two screws. Install the top spacer by clipping the spacer into the wall brackets and attaching it to the heater with 2 screws. 2 screws Spacer Top Spacer Wall Top Spacer Bracket Bracket Spacer Bracket Wall Bracket Rinnai Corporation EX08CT, EX11CT Manual...
  • Page 16: Gas Connection

    Supplied gas pressure must be within the limits shown in the Specifications section. • Refer to an approved pipe sizing chart if in doubt about the size of the gas line. Rinnai Corporation EX08CT, EX11CT Manual...
  • Page 17 * For the EX11CT with natural gas: Use A1, A2, A3, or A4 for venting up to 7 feet (2.1 m) with one elbow. Use A5, A6, A7, or A8 for venting exceeding 7 feet (2.1 m) with one elbow. Rinnai Corporation EX08CT, EX11CT Manual...
  • Page 18 Yellow flames or an orange color is abnormal and maintenance is required. NORMAL Flame Rod Long, clear, blue, stable flames ABNORMAL Flame Rod Yellow flames or orange color Rinnai Corporation EX08CT, EX11CT Manual...
  • Page 19 B149.1. If installed in a manufactured home, the installation must conform with the Manufactured Home Construction and Safety Standard, Title 24 CFR, Part 3280 and/or CAN/SCA Z240 MH Series, Mobile Homes. □ Leave the entire manual with the consumer. Rinnai Corporation EX08CT, EX11CT Manual...
  • Page 20: Dimensions

    Dimensions inches (mm) A full size template is provided on the NOTICE 10.1 in cardboard packaging. 257 mm 6.8 in 3.3 in DO NOT DISCARD until installation is 172 mm completed. Rinnai Corporation EX08CT, EX11CT Manual...
  • Page 21: Specifications

    46 lbs (21 kg) Noise Level 27-36 dB Rinnai is continually updating and improving products. Therefore, specifications are subject to change without prior notice. The efficiency rating of this appliance is a product thermal efficiency rating determined under continuous operating conditions and was determined independently of any installed system.
  • Page 22: Direct Vent Furnace Operation Instructions

    EX11CT ....(RHFE-265FTA2) Important Facts about your Direct Vent Furnace Thank you for purchasing a Rinnai Direct Vent Furnace. For proper operation and safety, it is important to follow the instructions and adhere to all safety precautions. Read all of the instructions and the warranty thoroughly before operating this heater. Keep this manual in a safe place.
  • Page 23: Safe Operation

    Keep burner ON/OFF button on the control panel. and control compartment clean. 3.Locate the manual gas valve on the side of the unit. Turn the manual valve clockwise to the full OFF position. Rinnai Corporation EX08CT, EX11CT Manual...
  • Page 24: Getting To Know Your Appliance

    ON THE LEFT HOLD BOTH SIDES AND PULL TOWARD AIR FILTER VENT TERMINAL GAS CONNECTION COMBUSTION/AIR 1/2” MALE NPT EXHAUST EXHAUST PIPE POWER CORD PLUG 120V AC, 60 Hz COMBUSTION AIR INTAKE HOSE ROOM TEMPERATURE SENSOR/THERMISTOR Rinnai Corporation EX08CT, EX11CT Manual...
  • Page 25: Control Panel

    If activated while the heater is OFF, then all controls will be locked. • If the heater is turned off while the Child Lock is activated, it cannot be turned on again until the lock is deactivated. • Deactivating the lock releases the control buttons. Rinnai Corporation EX08CT, EX11CT Manual...
  • Page 26: Remote Thermostat Mode (Optional Accessory)

    DISPLAY in either mode. Error codes will not show on the remote thermostat even when in remote thermostat mode.) ATTENTION The remote thermostat will NOT control the heaters ability to power on or power down. This must still be done by using the ON/OFF button of the heater. Rinnai Corporation EX08CT, EX11CT Manual...
  • Page 27: Setting The Clock

    The timers can be set while the heater is on or off. To current timer period. operate the timer, the heater must be on. Setting the timers: 1. Press the “Set Times” button twice to set Timer 1. Rinnai Corporation EX08CT, EX11CT Manual...
  • Page 28: Economy (Energy Saving Mode)

    (Default setting at the factory is on.) NOTICE The Set Back feature is intended to prevent the installation location from falling below a specified temperature. It is not intended as an alternate thermostat, but rather a preventative measure against freezing. Rinnai Corporation EX08CT, EX11CT Manual...
  • Page 29: Humidifier And Air Flow Direction

    Use a screw driver or similar object to bend each louver to the desired position. Do not bend repeatedly (no more than 5 times) or else the louver will break. The horizontal louvers (which determines the vertical air flow direction) are fixed and cannot be adjusted. Rinnai Corporation EX08CT, EX11CT Manual...
  • Page 30: Required Care And Maintenance Care And Maintenance

    All maintenance and service is to be performed by a Dirty filters reduce the air flow qualified service technician, preferably one who has and the appliance’s ability to attended Rinnai service training classes on the Direct produce heat. The filters should Vent products. be cleaned frequently during the heating season.
  • Page 31: Before Making A Service Call

    Unit shuts off without apparent reason. Check whether filters are blocked. Dirty filters will cause the heater to overheat. Power Failure. Switch OFF, then ON again when power is restored to re-set controls. Rinnai Corporation EX08CT, EX11CT Manual...
  • Page 32: Diagnostic Codes And Remedies

    You may be able to clear the fault code by turning the furnace off and then on again. If the fault code remains or returns on the next operation, contact Rinnai or your nearest service agent and arrange for a service call.
  • Page 33: Restart Function

    Clear Obstruction Air Filter Blocked Clean Filter Gas Escape Service Call Child Lock Set Cancel Child Lock Gas Off at Meter, Turn Gas On Tank, or Valve ON Timer is set Cancel “ON” Timer No Display Rinnai Corporation EX08CT, EX11CT Manual...
  • Page 34: Cut-Away Diagram

    Cut-Away Diagram Rinnai Corporation EX08CT, EX11CT Manual...
  • Page 35: Wiring Diagram

    THERMAL FUSE CONVECTION FAN MOTOR FUSE SPARKER white ELECTRODE SV1, 2 MAIN SOLENOID VALVE 1, 2 yellow MODULATING SOLENOID COMBUSTION FAN MOTOR VALVE gray TRANSFORMER PRESSURE SENSOR orange FLAME ROD W. TH WALL THERMOSTAT brown Rinnai Corporation EX08CT, EX11CT Manual...
  • Page 36: Ladder Diagram

    Fuse Sparker Electrode SV1, 2 Main solenoid valve 1,2 Modulating Combustion fan solenoid valve motor Transformer Fan control circuit Flame rod Main burner Pressure sensor Central processing unit Convection Fan W. TH Wall Thermostat Rinnai Corporation EX08CT, EX11CT Manual...
  • Page 37: Parts List

    Parts List / Liste de Pièces For replacement parts call Rinnai at 1-800-621-9419. Pour les pièces de rechange, appelez Rinnai au 1-800-621-9419. Rinnai Corporation EX08CT, EX11CT Manual...
  • Page 38 Parts List / Liste de Pièces Rinnai Corporation EX08CT, EX11CT Manual...
  • Page 39 Parts List / Liste de Pièces Rinnai Corporation EX08CT, EX11CT Manual...
  • Page 40 Parts List / Liste de Pièces Rinnai Corporation EX08CT, EX11CT Manual...
  • Page 41 Parts List / Liste de Pièces Rinnai Corporation EX08CT, EX11CT Manual...
  • Page 42 Combustion Chamber Fixer 556F-215 fixation de chambre de combustion Fixing Plate 209000077 plaque de fixation Seal Plate Packing 206000014 garniture de plaque d’étanchéité Seal Plate B 206000013 plaque d’étanchéité B Flange Board 209000020 panneau de bride Rinnai Corporation EX08CT, EX11CT Manual...
  • Page 43 209000085 Clip J 147 Air Inlet A 553F-340-1 arrivée d’air A 148 Air Inlet Packing RHF300F-79 garniture d’arrivée d’air * Kit 205000060 includes electrode mounting plate, electrode, electrode packing, and burner box fitting plate assy. Rinnai Corporation EX08CT, EX11CT Manual...
  • Page 44 711 SV.IG Harness 205000042 toron d’allumeur 712 Power Supply Cord cordon d’alimentation 205000043 713 FR Lead 431F-1430 liaison FR 714 Pressure Sensor 205000057 détecteur de pression 715 SUB-P.C.B Harness A 205000092 Harnais de carte PC secondaire Rinnai Corporation EX08CT, EX11CT Manual...
  • Page 45 Conversion Kits (Optional) / Kits de conversion (facultatifs) Model For converting to NG For converting to Propane (Modèle) (Pour la conversion NG) (Pour la conversion Propane) EX08CT (RHFE-202FTA2) 204000033 204000037 EX11CT (RHFE-265FTA2) 204000034 204000038 Rinnai Corporation EX08CT, EX11CT Manual...
  • Page 46: Warranty

    What will Rinnai do? Rinnai will repair or replace the covered product or any part or component that is defective in materials or workmanship as set forth. Rinnai will pay reasonable labor charges associated with the repair or replacement of any such part or component.
  • Page 47 Rinnai will replace the product with a comparable product at Rinnai’s discretion. If a component or product returned to Rinnai is found to be free of defects in material or workmanship, or damaged by improper installation or damaged during return shipping, the warranty claim for product, parts and labor may be denied.
  • Page 48 NOTES Rinnai Corporation EX08CT, EX11CT Manual...
  • Page 49: French Version

    Si vous ne pouvez pas joindre votre fournisseur de gaz, appelez les pompiers. — Installation et interventions de service doivent être effectuées par un professionnel agréé. Enregistrez votre produit sur www.rinnairegistration.com ou téléphonez au 1-866-RINNAI1 (746-6241) Manuel EX08CT, EX11CT de Rinnai Corporation...
  • Page 50: Définitions De Sécurité

    à vous contacter nous-mêmes avec des informations relatives au(x) produit(s) que vous avez enregistré(s) et/ou sur votre compte chez nous. Si vous avez des questions, ou pensez que ce manuel est incomplet, contactez Rinnai au 1-800-621-9419. Importantes informations de sécurité...
  • Page 51: Comportements Et Pratiques De Sécurité Pour Le Consommateur Et L'istallateur

    Ce produit peut vous exposer à des produits chimiques, y compris le di (2-éthylhexyl) phthalate (DEHP) et le bisulfure de car- bone qui sont connus dans l'État de Californie pour causer le cancer, des malformations congénitales ou d'autres problèmes de reproduction. Pour plus d'informations, visitez www.P65Warnings.ca.gov. Manuel EX08CT, EX11CT de Rinnai Corporation...
  • Page 52: Instructions D'installation (Pour Professionnel Agréé) Réglementations D'états

    Instructions d’installation (pour professionnel agréé) - Réglementations d’états AVIS AVANT TOUTE INSTALLATION L’appareil Rinnai à ventilation directe doit être installé par un sous-traitant qualifié ou agréé au niveau de la province, ou un installateur Rinnai correctement formé. Si vous n’avez pas reçu la formation appropriée, vous ne devez pas installer cet appareil.
  • Page 53: Installation Des Composants De La Ventilation Inclus

    9 1/2 - 15 3/4 in (240 - 400mm) C Vent Kit FOT-153 15 3/4 - 23 5/8 in (400 - 600 mm) D Vent Kit FOT-154 23 5/8 - 31 1/2 in (600 - 800 mm) Manuel EX08CT, EX11CT de Rinnai Corporation...
  • Page 54: Instructions D'installation

    • Rinnai recommande d’utiliser un circuit d'alimentation secteur dédié, 120 V/60 Hz, pouvant fournir 10 ampères. Manuel EX08CT, EX11CT de Rinnai Corporation...
  • Page 55: Préparation Pour L'installation

    • • Isolant pour tuyaux Bouchons serre-fils • Chevilles pour murs en béton • Cache-tuyau optionnel • Contrôleur de température optionnel • Câble à deux conducteurs 22 AWG pour le contrôleur Manuel EX08CT, EX11CT de Rinnai Corporation...
  • Page 56: Dégagements De Sortie D'évacuation

    Dégagement au-dessus de niveau du sol, véranda, porche, plate-forme ou balcon 12 po (30 cm) 12 po (30 cm) EX08CT - 6 po (15 cm) EX08CT - 6 po (15 cm) Dégagement par rapport à porte ou fenêtre pouvant être ouverte...
  • Page 57: Dégagement Par Rapport Aux Combustibles

    Construction de maison préfabriqué et sécurité, Titre 24 CFR, Partie 3280 et/ou à la norme Rinnai recommande un dégagement de 254 mm (10") à canadienne CAN/SCA Z240 Série MH (Maisons partir du dessus et des deux côtés pour les interventions de mobiles).
  • Page 58: Installation Du Collecteur Cheminée

    Le collecteur de cheminée doit sortir sur l’extérieur. N’évacuez L’appareil ne peut être utilisé qu’avec l’un des cinq types de kit pas dans d’autres pièces; de cheminée Rinnai. Ces kits de cheminée et leurs dimensions sont listés en page précédente. •...
  • Page 59 Fixez la connexion intérieure avec 3 vis. La connexion intérieure peut toujours être tournée pour installer les vis. 3 vis Manuel EX08CT, EX11CT de Rinnai Corporation...
  • Page 60: Installation Du Kit D'extension

    NFPA 54 et doivent rester tuyau A accessibles pour permettre leur inspection et réparation. Des caches décoratifs sont disponibles chez Rinnai. Ces illustrations montrent 3 façons possibles d’orienter l’extension de la conduite d’évacuation et du tuyau d’admission d’air en partant du collecteur de fumée.
  • Page 61 Jonction de tuyaux tuyau, et sur l’autre moitié dans un deuxième tuyau. Ne coupez pas le tuyau d’amission AVIS d’air. Cela pourrait générer du bruit. Tuyaux d’admission d’air Manuel EX08CT, EX11CT de Rinnai Corporation...
  • Page 62 Joint de tuyaux - 2.0 po (50 mm) diamètre intérieur Arrêt de tuyau A Arrêt de tuyau B Collier de tuyaux 2 sets 3 sets 4 sets Dispositif mural Écrou Vis A Vis B Manuel EX08CT, EX11CT de Rinnai Corporation...
  • Page 63: Raccordement De L'appareil

    2 vis. 2 vis Espaceur supérieur Espaceur supérieur Patte d’espaceur Support mural Patte d’espaceur Support mural Manuel EX08CT, EX11CT de Rinnai Corporation...
  • Page 64: Branchment Du Gaz

    être dans les limites montrées dans la section Spécifications. • Référez-vous au tableau de calibre de tube approuvé si vous avez un doute sur la taille de la conduite de gaz. Manuel EX08CT, EX11CT de Rinnai Corporation...
  • Page 65 * Pour le EX11CT au gaz naturel : utilisez A1, A2, A3 ou A4 pour ventilation jusqu'à 7 mètres (2.1 m) avec un coude. utilisez A5, A6, A7 ou A8 pour ventilation supérieure plus 7 mètres (2.1 m) avec un coude. Manuel EX08CT, EX11CT de Rinnai Corporation...
  • Page 66 120 V CA/60 Hz avec circuit alimenté et bien relié à la terre. □ Confirmez qu’il n’y a PAS eu d’adaptateur de fiche ni de cordon de rallonge utilisés avec le générateur d’air chaud. Manuel EX08CT, EX11CT de Rinnai Corporation...
  • Page 67 à la norme américaine pour Construction de maison préfabriqué et sécurité, Title 24 CFR, Part 3280 et/ou à la norme canadienne CAN/SCA Z240 MH Series (Maison mobile). □ Laissez le manuel complet au consommateur Manuel EX08CT, EX11CT de Rinnai Corporation...
  • Page 68: Dimensions

    Dimensions Un modèle de taille complète est fourni sur AVIS 10.1 in l'emballage en carton. 257 mm NE JETEZ pas jusqu'à ce que l'installation est 6.8 in 3.3 in terminée. 172 mm 85 mm Manuel EX08CT, EX11CT de Rinnai Corporation...
  • Page 69: Spécifications

    Volume de ventilation 27-36 dB Rinnai poursuit constamment la mise à niveau et l’amélioration de ses produits. De ce fait ces spécifications sont su- jettes à changement sans préavis. Le rendement énergétique de cet appareil mesure l’efficacité thermique du produit en utilisation continue, il a été...
  • Page 70: Instructions D'utilisation Générateur D'air Chaud

    AVIS : Rinnai partage parfois des informations de contact de clients avec des entreprises qu’il estime pouvoir fournir des produits ou services qui peuvent vous être utiles. En communicant ces informations, vous donnez votre accord pour que nous communiquions vos informations de contact dans ce but.
  • Page 71: Fonctionnement Sans Risques

    Repérez le robinet de coupure manuelle de gaz sur le côté du chauffage. Tournez-le dans le sens horaire jusqu’à la fermeture totale (position OFF). REMARQUE : Le ventilateur va continuer de tourner jusqu’au Manuel EX08CT, EX11CT de Rinnai Corporation...
  • Page 72: Connaissance De Votre Appareil

    TENIR LES DEUX CÔTÉS ET TIRER VERS VOUS FILTRE À AIR TERMINAISON DE CONNEXIONS DE GAZ VENTILATION 1/2 mâle NPT COMBUSTION/ ÉVACUATION CONDUITE D’ÉVACUATION FICHE PLUG 120V AC, 60 Hz TUYAU D’ADMISSION D’AIR DE COMBUSTION THERMISTANCE Manuel EX08CT, EX11CT de Rinnai Corporation...
  • Page 73: Panneau De Commandes

    Si le chauffage a été arrêté pendant que le verrouillage est activé, il ne pourra pas être remis en marche avant que le verrouillage ne soit désactivé. • La désactivation du verrouillage libère les boutons de commande. Manuel EX08CT, EX11CT de Rinnai Corporation...
  • Page 74: Mode À Thermostat Distant (Accessoire Optionnel)

    à thermostat distant). Le thermostat à distance NE contrôlera PAS la capacité des appareils de chauffage à ATTENTION s'allumer ou à s'éteindre. Cela doit toujours être fait en utilisant le bouton ON / OFF du chauffage. Manuel EX08CT, EX11CT de Rinnai Corporation...
  • Page 75: Réglage De L'horloge

    Override retournera l'appareil de chauffage à Réglage des minuteries: l'exploitation de la période de temporisation en cours. Appuyez sur le bouton Set Times deux fois pour régler la minuterie 1. La lumière à côté de "Timer 1 sur" doit Manuel EX08CT, EX11CT de Rinnai Corporation...
  • Page 76: Économie (Mode D'économie Énergétique)

    La fonction Set Back permet d'éviter que l'emplacement d'installation ne tombe en dessous d'une température spécifiée. Il n'est pas conçu comme un thermostat de 30 mi- 30 mi- rechange, mais plutôt comme une mesure préventive contre le gel. Manuel EX08CT, EX11CT de Rinnai Corporation...
  • Page 77: Humidificateur Et Direction De Flux D'air

    Utilisez un tournevis ou un outil similaire pour fléchir chaque latte dans la position voulue. Ne faites pas cette opération fréquemment (pas plus de 5 fois) sinon le registre peuvent casser. Le registre horizontal (qui détermine la direction en hauteur du flux d'air) est fixe et ne peut pas se régler. Manuel EX08CT, EX11CT de Rinnai Corporation...
  • Page 78: Entretien Et Maintenance Entretien Et Maintenance

    Des filtres sales réduisent le flux doivent être menées par un technicien de service qualifié, d’air et la capacité de l’appareil à ayant de préférence suivi les cours de formation de Rinnai produire de la chaleur. Les filtres sur les produits à ventilation directe.
  • Page 79: Avant De Demander Une Intervention

    Regardez si les filtres sont saturés. Cela peut causer une surchauffe de l’appareil. Unit cuts off without apparent reason. Check whether filters are blocked. Dirty filters will cause the heater to overheat. Power Failure. Switch OFF, then ON again when power is restored to re-set controls. Manuel EX08CT, EX11CT de Rinnai Corporation...
  • Page 80: Codes De Diagnostic

    à la remise en défaut pour aider à diagnostiquer le problème. Ce code de route, contactez Rinnai ou votre agent de service le plus défaut va clignoter à l’afficheur du panneau de commandes.
  • Page 81: Fonction De Redémarrage

    Demande d’intervention Fonction de verrouillage activée ● Déverrouiller Coupure de gaz en amont (compteur, Rétablir l'arrivée du gaz ● réservoir ou vanne) ON Timer est définie. Annuler "ON" bois ou push ● remplacer bouton Manuel EX08CT, EX11CT de Rinnai Corporation...
  • Page 82: Vue En Coupe

    RACCORDEMENT DE THERMIQUE CHAMBRE DE COM- BUSTION BRÛLEUR PORT DE VUE DE FLAMME THERMISTANCE REGISTRE D’AIR SECONDAIRE ÉLECTRODE DISTRIBUTEUR REGISTRE BAC D’HUMIDIFICATION INTERRUPTEUR DE SUR- CHAUFFE N° 2 CAPOT INFÉRIEUR INJECTEUR CORDON D’ALIMENTATION SECTEUR Manuel EX08CT, EX11CT de Rinnai Corporation...
  • Page 83: Schéma De Câblage

    INTERRUPTEUR DE SURCHAUFFE 1, 2 gr/y Vert/jaune FUSIBLE THERMIQUE rouge FUSIBLE ÉCLATEUR blanc ÉLECTRODE SV1, 2 ÉLECTROVANNE 1,2 jaune VANNE MODULATRICE gris TRANSFORMATEUR DÉTECTEUR DE PRESSION orange W. TH THERMOSTAT MURAL brun UNITÉ AFFICHAGE-COMMANDE Manuel EX08CT, EX11CT de Rinnai Corporation...
  • Page 84: Diagramme En Escalier

    Diagramme en escalier CODE COLOR noir bleu vert gr/y Vert/jaune rouge blanc jaune gris orange brun Manuel EX08CT, EX11CT de Rinnai Corporation...
  • Page 85: Garantie

    2 ans à partir de l’achat Rinnai va réparer ou remplacer le produit couvert, ou n’importe quelles de ses parties ou composants étant défectueux du fait des matériaux ou de la main-d’œuvre, comme c’est explicité dans le tableau précédent. Rinnai paiera des coûts de main- d’œuvre raisonnables associés à...
  • Page 86 Garantie limitée (suite) Le remplacement du produit ne peut être autorisé que par Rinnai. Rinnai n’autorise aucune personne ou société à assumer en son nom une quelconque obligation ou responsabilité de remplacement du produit. Si Rinnai détermine qu’une réparation d’un produit est impossible, Rinnai peut le remplacer par un produit comparable à...
  • Page 87 NOTES Manuel EX08CT, EX11CT de Rinnai Corporation...
  • Page 88 107517 RHF265-1107X02(00) 200000072(02) 5/2018...

This manual is also suitable for:

Ex11ctRhfe-202fta2Rhfe-265fta2

Table of Contents