B-35
If the passcode does not equal zero (0000), enter the
passcode now. If the passcode has been forgotten, a
p.c. computer application or Palm O.S. application is
required to change the passcode
Memory Value
WAVEFORM CONTROL TECHNOLOGY
200
IR PORT
Weld WFS
WELD MODE
ARC CONTROL
Parameter Name
If the passcode has been set to zero (0000), SETUP will
illuminate on the MSP4 panel and the display will show
the following:
Four items show on the MSP4 panel.
• Memory Value
• High Limit
• Low Limit
• Parameter Name
One of these items will flash to indicate which item will
change when the MSP4 encoder is rotated.
right button on the MSP4 panel to select the item to
change.
The Limits Setup menu shows a list of all parameters
available for the weld mode stored in the memory cho-
sen. For example, if limits are being set for a stick
(SMAW) mode, parameters such as Run-in WFS and
Postflow will not appear.
To lock a parameter to a specific value that cannot
be changed, set the high and low limits to the
same value.
WAVEFORM CONTROL TECHNOLOGY
200
IR PORT
Weld WFS
WELD MODE
ARC CONTROL
Rotate to
Change
Value.
All manuals and user guides at all-guides.com
OPERATION
High Limit
Low Limit
Hi Hi
= 200
Lo
Lo
= 180
SETUP
START OPTIONS
END OPTIONS
SET
Press the
Hi Hi
= 200
Lo
Lo
= 180
SETUP
START OPTIONS
END OPTIONS
SET
Press to
select item
to change.
POWER FEED™ 25M
The memory value must always be less than or equal
to the high limit, and greater than or equal to the low
limit.
After setting limits, press the memory button with the
flashing LED. The MSP4 will ask to save or discard
the limit changes just made. Press the left MSP4 for
button (YES) to save and enable the limits and exit.
Press the right MSP4 button (NO) to exit and leave
limits unchanged.
Enabling/Disabling Limits
Enable/Disable
Limits: Press
10 seconds
M
PROCEDURE
A
GUN B
1
2
HOLD 2 SECONDS TO SAVE
4
5
Limits for each memory may be enabled or disabled
by pressing and hold the appropriate memory button
for 10 seconds. Release the memory button when the
MSP4 display shows the following:
WAVEFORM CONTROL TECHNOLOGY
IR PORT
Enable/Disable
WELD MODE
ARC CONTROL
If the passcode does not equal zero, enter the passcode
now. If the passcode is zero (0000), SETUP will light
and the MSP4 displays the following:
WAVEFORM CONTROL TECHNOLOGY
IR PORT
Yes
WELD MODE
ARC CONTROL
Press the left MSP4 button (YES) to enable limits or
the right MSP4 button (NO) to disable limits. Disabling
limits does not change any limits values that may
have been previously set.
B-35
MEMORY
M
3
6
Memory 1
Limits
SETUP
START OPTIONS
END OPTIONS
SET
Enable
Limits?
SETUP
No
START OPTIONS
END OPTIONS
SET