8.4 Closing SMA DC Disconnect
1. Position the lid onto the SMA DC Disconnect. Insert
the switch handle into the lid.
2. Turn the switch handle to position "0" (A).
3. Tighten the screw on the right side of the switch handle (B) using a small phillips screwdriver
(used screw: UNC no 5 x
4. Install the screw and washer at the bottom side of the SMA DC Disconnect (C), to fasten the lid.
The teeth of the washer must face toward the lid in order to ensure proper grounding. Tighten
the screw to a torque of 44 in‑lbs. (5 Nm).
Installation Guide
3
 in. cross recess Phillips pan head machine screw).
4
Opening and closing
SB8-10TL-IUS103811