BenQ PB6100 Service Manual page 43

Benq projector service manual
Hide thumbs Also See for PB6100:
Table of Contents

Advertisement

PB6100 Lamp on Sequence
Signal
Voltage Change
POWERON Low High
RESETZ
Low High
LAMPEN
Low High
LAMPLIT Low High
PB6100 Normal Lamp off Sequence
Signal
Voltage Change
RESETZ
High Low
LAMPEN
High Low
LAMPLIT High Low
POWERON High Low
1. This signal should go from low to high after all
the DC supplies are within spec. Then RESETZ
can go high.
2. After the power key pressed 3 second
continuously, the POWERON signal will
activate.
DMD is working, when the DMD reset.
Lamp lights up.
Indicate "Lamp on".
DMD is off.
Lamp is off.
Indicate "lamp off".
Power down the system, but the peripherals of the
CPU still power on.
Description
Description
43

Advertisement

Table of Contents
loading

This manual is also suitable for:

Pb6200

Table of Contents