ECOTRONIC Plus

1. Installation

1.1 Mounting

1.
2.
3.
4.
4
|
WARNING!
Always disconnect the controller
from power supply before open ing
the housing!
The unit must only be located in dry interior locations. It
is not suitable for installation in hazardous locations and
should not be placed close to any electromagnetic fields.
The controller must additionally be supplied from a double
pole switch with contact gap of at least 3 mm. Please pay
attention to separate routing of sensor cables and mains
cables.
1. Unscrew the cross-head screw from the cover and remo-
ve it along with the cover from the housing. Afterwards,
unscrew cross-head screws from the terminal cover and
remove the terminal cover.
2. Mark the upper fastening point on the wall and drill and
fasten the enclosed wall plug and screw leaving the head
protruding.
3. Hang the housing from the upper fastening point and
mark the lower fastening point through the hole in the
terminal box (centres 160 mm). Drill and insert the lo-
wer wall plug and insert the lower fastening screw and
tighten.
4. Connect relay, sensor and mains cables in accordance
with the terminal allocation and secure with strain relief.
5. Insert terminal cover and housing cover and attach with
the cross-head screws.
Advice:
Cable trunkting (e.g. 60 x
110 mm²) should be mount-
ted directly below the con-
troller in order to facilitate
the connection and sepa-
ration of mains and sensor
cables.The cables must be
inserted into the terminal
block with the stripped ca-
ble ends ensuring no stray
wires.