4.4 Menu: Expert

System warning "DT too high"
Expert/DT too high
selection: "Yes", "No"
factory setting: "Yes"
g
System warnin
"Non-ret. valve"
Expert/non-ret. val.
selection: "Yes", "No"
factory setting: "Yes"
Message relay (error message)
Expert/message rel.
selection: "Yes", "No"
factory setting: "No"
Chimney sweeper
Expert/chimney
selection: "Yes", "No"
factory setting: "No"
Expert/chimney sweeper
Sensor offset
Expert/Sensors/CS-Type
selection: A, B, C, D, E
factory setting: E
Expert/Sensors/CS-Adjust
Expert/Sensors/CS-Offset
Expert/Sensors/Sensor 1 (...12)
adjustment range: -5,0 ... 5,0 K
factory setting: 0,0 K
40
|
This message is shown, if solar loading has been carried out
for a period of 20 minutes with a differential higher than
50 K.
The message function can be deactivated by selecting
"No".
This message is shown if between 11 p.m. and 5.00 a.m. the
collector temperature is higher than 40 °C or a store is
loaded because of a high temperature difference.
The message function can be deactivated by selecting
"No".
Activate this function by selecting "Yes". If the controller
detects a fault, the message relay is energised (e.g. for signal
lights).
These errors are:
• Sensor defective
• Real-time-clock (RTC) defective
• Storage module (EEPROM) defective
Please note that a message caused by one of the plausibility
controls (non-return valve, DT too high) does not activate
the relay.
This function is used for activating a given relay state when
required.- e.g.flue gas measurement if the system controls
a boiler. Activate this function by selecting "Yes".
Adjust the required relay status in the chimney sweeper
menu (expert / chimney sweeper).
If the chimney sweeper function is activated, "chimney
sweeper" is indicated in the main menu.
Adjust the CS-type in this menu. The CS-type should be
matched to the code letter printed on the CS type label.
The CS-offset adjustment should be carried out with the
irradiation sensor disconnected.
Furthermore, an offset for sensors 1 ... 12 can be carried
out.