Overview
text display with menu navigation
15 sensor inputs
9 relay outputs
7 basic solar systems
add-on options and functions
function blocks can be allocated as
temperature differential functions
and thermostat functions
VBus
and RS232-interface
®
parametrisation and control of the
system via the Service Center Soft-
ware
The controller ECOTRONIC Plus is preprogrammed for
7 larger basic systems and allows the control of more
complex solar systems. The controller is equipped with a
multi-lingual menu, 9 relay outputs and 15 sensor inputs as
well as a multitude of add-on functions and options, which
enable the adaptation of the controller to individual solar-
and heating-systems. Additionally, the controller offers up
to two integrated calorimeters and allows the control of a
Technical data:
Housing: plastic, PC-ABS and PMMA
Protection type:
IP 20 / DIN 40 050
Ambient temp.: 0 ... 40 °C
Dimensions: 260 x 216 x 64 mm
Installation: wall mounting, also suit-
able for mounting into patch panels
Display: 4-line LC-text display (illumi-
nated), menu navigation (multi lingual),
bicoloured LED
Operation: 3 push buttons at the
front of the housing
Functions: Solar system controller for
use in solar and heating systems. Two
integrated calorimeters and control
of a wheather-compensated heating
weather-compensated heating circuit. ECOTRONIC Plus
is equipped with an interface for communication with the
Service Center Software. The software allows a comfortable
configuration, control and evaluation of the controller and
the solar systems.
circuit. Adjustable system parameters
and additional options (menu-driven),
balancing and diagnostic functions,
function control according to BAW-
guidelines.
Sensor inputs: 15 sensor inputs for
Pt1000, RTA11-M, V40 and CS10
Relay outputs: 9 relay outputs, 4 of
standards relays, 4 semi-conductor
relays, and 1 potential-free (floating)
relay.
Bus: VBus
, RS232
®
Power supply: 210 ... 240 V~,
50 ... 60 Hz
Switching capacity:
1 A (semiconductor relay)
4 A electromechanical and potential-
free relay
6,3 A (sum of all relays)
220 ... 240 V
Degree of pollution: 2
Rated impulse voltage: 2,5 kV
Mode of operation: type 1.c
Attention: Electrostatic dis-
charge can cause damage of
electronic components
Warning: high-voltage com-
ponents
3
|