ECOTRONIC Plus

3.4 Adjusting the controller step-by-step

Before adjusting the controller, select the language (Expert/language/...).
Points 1. – 3. have to be adjusted for all systems, points 4. – 18. aree adjusted optional to suit the system requirements,
points 19. and 20. should be adjusted before the system is handed over to the operator.
1. Select basic solar system
(Solar/Options/System)
2. Select hydraulic variant (beginning with system 2)
(Solar/Options/loading)
3. Adjust date and time
(arrangement/adj. values/time)
4. Activate internal heating circuit module if needed
(arrangement/heat. circuits/Options/heat. circ.)
5. Adjust parameters for internal heating circuit module
(Arrangement/heat. circuits/heat. circ./...)
6. Activate external heating circuit module if needed
(arrangement/heat. circuits/Options/HC module)
7. Adjust parameters for external heating circuit module
(arrangement/heat. circuits/Hc Module/...)
8. Activate desired functions with relay allocation (if needed)
Bypass
(Solar/Options/Bypass)
External heat exchanger
(Solar/Options/Ext. heat. ex)
Cooling function
(Solar/Options/cool. func.)
Parallel relay
(Solar/Options/Par.Relay)
After-heating suppression
(Solar/Options /ah suppress.)
HSE
(arrangement/Options/hse)
Store loading
(arrangement/Options /store load.)
Error message
(Expert/message rel.)
9. Activate further functions without relay allocation (if
needed):
Tube collector function
(Solar/Options/tube col.)
Collector cooling function
(Solar/Options/col. cooling)
Recooling function
(Solar/Options/Recooling)
Frost protection
(Solar/Options/frost. prot.)
Target temperature
(Solar/Options/target tem.)
CS-Bypass
(Solar/Options/CS-Bypass)
10. Adjust special parameters of the selected options
(Solar/adj. values/...),
(Solar/Expert/...) and
(Arrangement/adj. values/...)
11. Activate functions of function blocks (if needed)
(arrangement/Options/...)
12. Adjust switching conditions for the activated functions
(Arrangement/adj. values/...)
13. Activates heat measurement function(s) (if needed)
(WMZ/Options/...)
14. Adjust special parameters
(WMZ/WMZ 1 (2)/Expert/...)
15. Deactivate warning message (if needed)
(Expert/...)
16. Carry out sensor offset (if needed)
(Expert/Sensors/...)
17. Increase minimum speeds (if needed)
(Expert/Relay/...)
18.Setup and adjust chimney sweeper function (if needed)
(Expert/chimney sweeper/...)
19. Carry out relay test
(manual operation/...)
20. Save adjustments
(user code/000)
15
|