A. If the valve stop (13) and set screw (7) did not
separate during disassembly, screw them into the
spool (5) and torque valve stop from 85 to 100 in–lb.
B. If the valve stop (13) and set screw (7) separated
during disassembly, screw the set screw completely
into the spool (5). Then loctite the exposed threads
and screw the valve stop onto the set screw and
spool. Torque valve stop from 85 to 100 in–lb.
Hydraulic System
4. Coat spool (5) with clean hydraulic oil and carefully
push and twist spool into the valve housing (9). Ensuring
not to damage the seals.
5. Install plug (2) and new O–ring (3) into the spool (5).
Torque plug from 85 to 100 in–lb.
6. Press valve cap (1) onto valve housing (9). If the
valve cap is damaged or will not fit tightly onto the the
valve housing, replace the valve cap with a new one.