Procedure for Reel Motor Case Drain Check:
1. Make sure hydraulic oil is at normal operating tem-
perature by operating the machine for approximately 10
minutes. Make sure the hydraulic tank is full.
2. Make sure machine is parked on a level surface with
the cutting units lowered. Make sure engine is off and
the parking brake is engaged.
CAUTION
Operate all hydraulic controls to relieve
system pressure and avoid injury from
pressurized hydraulic oil.
Motor
Manifold Port
Position
(Case Drain)
Right Hand
D1
Left Hand
D2
Rear
D3
3. On suspected bad motor, clean hose connection
and disconnect hose from motor that returns to the man-
ifold (see table).
IMPORTANT: Make sure oil flow indicator arrow on
the flow gauge is showing that the oil will flow from
the motor through the tester and into the hose.
4. Install tester in series with the motor and the discon-
nected return hose. Make sure the flow control valve is
fully open.
5. Make sure backlap knob on the valve block is in the
mow position.
6. One person should sit on the seat and operate the
machine while another person reads the tester. Start en-
gine and move the throttle to full speed (3200
RPM).
Reelmaster 2300–D/2600–D
7. Engage reels by pulling the knob on the instrument
panel out. While watching pressure gauges, slowly
close flow control valve until a pressure of 1200 PSI is
obtained.
8.
9. Clean hose fitting and disconnect hose from case
drain on the manifold block (see table). Plug the man-
ifold port.
Manifold Port
10. Put case drain hose into 1 quart container gra-
(Motor Return)
duated in ounces (1 liter container graduated in millili-
M1
ters).
M3
11. One person should sit on the seat and operate the
M6
machine while another person holds the hose and reads
the tester. Start engine and move the throttle to full
speed (3200
12. While sitting on seat, engage cutting units by pulling
the knob on the instrument panel out. Make sure gauge
pressure still reads 1200 PSI. After 15 seconds, push
knob on the instrument panel in to disengage cutting
units. Stop the engine.
13. Measure the amount of oil collected in the container.
Divide the number of ounces collected by 32 to get gal-
lons per minute. (Divide the number of milliliters col-
lected by 250 to get liters per minute).
14. Disconnect tester from motor and hose. Reconnect
hose to the pump.
15. Remove cap from manifold fitting. Reconnect case
drain hose to the motor.
100
16. If flow was greater than 0.7 GPM (2.6 LPM), repair
or replace the reel motor as necessary.
Page 4 – 33
CAUTION
Keep away from reels during test to pre-
vent personal injury from the rotating reel
blades.
Disengage cutting units and stop engine.
100 RPM).