7. Test Run the Bath with Airjets - Standard

NOTE: For additional information on operating the bath with airjets, see the "Confirm Proper Operation"
section.
Check all electrical connections. Make sure the electrical power to the bath with airjets is turned on.
Ensure all PVC piping connections are tightened.
Temporarily remove the protective drop cloth from the bath, then fill the bath to a level at least 2"
(5.1 cm) above the top of the highest airjet.
Operate the bath with air flow in all three zones. Check all bath PVC connections for leaks.
Stop the blower.
Check for water leakage at the bath, the bath drain, and the air harness.
Test other features as desired.
Drain the bath to start the automatic purge cycle.
Allow the automatic purge cycle to complete.
Place the protective drop cloth over the bath.
Turn off the power to the unit.