Quadra-Fire MT VERNON-AE Troubleshooting Manual page 24

Table of Contents

Advertisement

MT VERNON-AE TROUBLE SHOOTING MANUAL
The appliance must be in complete shutdown, completely
cool and the exhaust blower off before performing any
cleaning or maintenance. There is a risk of shock if
the appliance is not unplugged before servicing the
appliance.
NOTE: Performing this routine service will require approximately 20
minutes a month depending on type and quality of fuel you burn.
CLEANING OR
INSPECTION
FIREPOT
Softwood Pellets
FIREPOT
Hardwood Pellets
FIREPOT
Corn, Wheat, or Sun-
flower Seeds
ASHPAN
Wood Pellets
ASHPAN
Alternate Fuel
HEAT EXCHANGER
EXHAUST BLOWER
Baffle
Insert flat head screw driver into "V"
section and push down and the bottom
of the latch will fall forward off of post
9-30-2010
CAUTION
FREQUENCY
Every 5 bags
Every 3 bags
Every 1 bag
Every 5 bags
Daily
Every 1 ton of
fuel
Every 3 tons of
fuel
Latches
Locating ears - 1 on
each side. Fit behind
bottom edge.
PROPER SHUTDOWN PROCEDURE
1. Set the wall control thermostat to "OFF" on AUTOMATIC/
MANUAL SETTING screen and let the appliance com-
pletely cool. The exhaust blower must be off before you
can unplug the appliance before servicing.
2. Smoke spillage into the room can occur if the appliance
is not cool before unplugging.
DAILY
WEEKLY
-OR-
-OR-
X
-OR-
-OR-
X
-OR-
-OR-
-OR-
FIREPOT MAINTENANCE
The firepot floor and firepot air holes will need to be
scraped occasionally depending on the quality of fuel
being used. Use a putty knife, a flat head screwdriver
or the firepot clean-out tool provided to remove excess
carbon from the firepot.
PAGE 24
In 2 Weeks YEARLY
X
X
X
X
X
7020-057D