Siemens POS8.4420/109 Basic Documentation page 62

Room operator units
Hide thumbs Also See for POS8.4420/109:
Table of Contents

Advertisement

10
Appendix
Object list
393
1
17
UFS -
User
Fan
Speed
Setting
62 | 70
Interface
1
1
U16 /
PDT_UNSIGNE
Object type
D_INT
ObjectIndex
29
1
U8 /
PDT_UNSIGNE
D_CHAR
U8 /
DPT_Value_1_
Ucount
FanBoostRe
16
1
B1 /
q
2
PDT_BINARY_I
NFORMATION
FirePlaceRe
16
1
B1 /
q
3
PDT_BINARY_I
NFORMATION
KitchenHood
16
1
B1 /
Req
4
PDT_BINARY_I
NFORMATION
ResetTmpFa
16
B1 /
1
nReq
5
PDT_BINARY_I
NFORMATION
FanBoostPro
16
U16 /
1
PDT_UNSIGNE
longTime
6
D_INT
FirePlaceProl
16
1
U16 /
ongTime
7
PDT_UNSIGNE
D_INT
R
----
Fan Speed user's
setting
R
Rea
needed for Object
d.ind
Index Discovery via
LTE-Read onto this
Property
R
IR.re
FanBoostReq refers to
q
the optional process
output property of AB
UFS representing a
trigger command
requested by the room
occupant to initiate the
temporary Fan Boost
fan mode in HRV
applications
R
IR.re
FirePlaceReq refers to
q
the optional process
output property of AB
UFS representing a
trigger command
requested by the room
occupant to initiate the
temporary Fire Place
fan mode in HRV
applications.
R
IR.re
KitchenHoodReq
q
refers to the optional
process output
property of AB UFS
representing a trigger
command requested
by the room occupant
to initiate the
temporary Kitchen
Hood fan mode in
HRV applications.
IR.re
ResetTmpFanReq
R
q
refers to the optional
process output
property of AB UFS
representing a trigger
command requested
by the room occupant
to cancel an activated
temporary fan mode in
HRV applications.
IR.re
FanBoostProlongTime
R
refers to the optional
q
process output
property of AB UFS to
adjust the duration of
the temporary Fan
Boost ventilation mode
in HRV applications.
R
IR.re
FirePlaceProlongTime
q
refers to the optional
process output
property of AB UFS to
adjust the duration of
the temporary Fire
=> SD-
T060.0601_EN_SARB
_Data_Aquisition:
7.1.2.10.1
KNX Standard,
chapter 3-5-1,
PID_OBJECT_INDEX
=> cASA-[T022.S035-
2I055] Fan operation:
Fan Boost/Fire
Place/Kitchen Hood
=> cASA-[T022.S035-
2I055] Fan operation:
Fan Boost/Fire
Place/Kitchen Hood
=> cASA-[T022.S035-
2I055] Fan operation:
Fan Boost/Fire
Place/Kitchen Hood
=> cASA-[T022.S035-
2I055] Fan operation:
Fan Boost/Fire
Place/Kitchen Hood
=> [T022.S035-
2I058.020] Operation
of 'Fan Boost', 'Fire
Place' prolong time
settings
=> [T022.S035-
2I058.020] Operation
of 'Fan Boost', 'Fire
Place' prolong time
settings
A6V11471220_en--_e