Component Installation And Handling - Omron F160 Setup Manual

Vision sensor
Hide thumbs Also See for F160:
Table of Contents

Advertisement

Installation Precautions
Ambient Temperature
1,2,3...
1.
2.
3.
4.
Louver
Noise Resistance
Use the following measures to help increase noise resistance.
1,2,3...
1.
2.
Power cable
200 mm min.
1-1-2

Component Installation and Handling

OMRON Components
Use a Camera, Camera Cable, and Console designed specifically for the
F160.
Connecting Cables
Always turn OFF the F160's power before connecting or disconnecting a cam-
era or cable.
Handling the Camera
The Camera's case is connected to the 0V line in the internal circuits. Observe
the following precautions to prevent noise interference.
1,2,3...
1.
2.
3.
All manuals and user guides at all-guides.com
Maintain a minimum clearance of 50 mm above and below the F160 to im-
prove air circulation.
Do not install the F160 immediately above significant heat sources, such
as heaters, transformers, or large-capacity resistors.
Do not let the ambient operating temperature exceed 50°C (122°F).
Provide a forced-air fan cooling or air conditioning if the ambient tempera-
ture is near 50°C (122°F) so that the ambient temperature never exceeds
50°C (122°F).
Control panel
F160
Do not install the F160 in a cabinet containing high-voltage equipment.
Do not install the F160 within 200 mm of power cables.
200 mm min.
F160
Do not ground the Camera.
Do not remove the base attached to the Camera.
Do not remove the core attached to the F150-VS Camera Cable.
Section 1-1