Connecting through the Serial Interface

Item
OFF delay
RESET input: 15 ms max.
Other inputs: 0.7 ms max.
Internal circuits
+
Output Specifications
Item
Model
F160-C10E (NPN mode)
Output voltage
12 to 24 VDC
Load current
45 mA max.
ON residual voltage
2 V max.
OFF leakage current
0.1 mA max.
Internal circuits
CHECK
The I/O contacts are shared by the I/O terminals and I/O connector. The fol-
lowing diagram shows the wiring diagram for the STEP signal as an example.
I/O terminals
I/O connector
4-2

Connecting through the Serial Interface

The F160's serial interface (RS-232C/RS-422 connector) can be used to con-
nect input signals such as measurement triggers or output signals such as
measurement results. Additionally, data that has been set in the F160 can be
backed up in a personal computer.
Refer to the Communications Reference Manual for details on communica-
tions settings and I/O formats.
34
All manuals and user guides at all-guides.com
COM IN
Input
terminal
10%
Output terminal
Load
COM OUT
COMIN
STEP
COMIN
STEP
Specification
Input
terminal
COM IN
Specification
F160-C15E (PNP mode)
+
Section 4-2
COM OUT
Load
Output terminal