6.4 Compressor maintenance
Refer to Section 7: Parts List for the part numbers of all
items mentioned in this section.
Do not attempt any maintenance when the com-
pressor is running or pressurized. Stop the com-
pressor, relieve all internal pressure, and isolate
the power supply before performing mainte-
nance. Only a competent person, experienced in
compressor service, should perform any service,
including maintenance.
6.4.1
Adding compressor fluid
When adding compressor fluid, only use new fluid of the
same type that is already in the compressor. Using dirty
or used fluid may cause poor performance, foaming, and
clogging of the filter element, nozzle, or pipes.
WARRANTY INFORMATION
Mixing of fluids other than Sullube
compressor's warranty.
1. Shut down the compressor, bleed pressure
to zero, and allow the compressor to cool.
2. Slowly loosen the fluid filler cap by turning it
to the left by hand to allow any trapped air to
vent, then remove the cap.
3. Pour fluid into the fluid filler.
4. Replace the fluid filler cap by turning the cap
to the right by hand until it will not turn any
further. Ensure the O-ring is properly seated.
5. Run the compressor for a short period of
time and check the fluid level through the
sight glass, adding more fluid if necessary
(see Section 6.3.7: Compressor fluid levels).
6.4.2
Changing compressor fluid
When changing compressor fluid, only use new fluid of
the same type that is already in the compressor. Using
dirty or used fluid may cause poor performance, foaming,
and clogging of the filter element, nozzle, or pipes.