Checking The Air End Of A New Machine; Checking The Compressor Fluid Level; Checking The Isolation Gate Valve; Electrical Checks - Sullair ShopTek ST45 Operation & Maintenance Manual

Table of Contents

Advertisement

ShopTek™ ST45, ST55, ST75 (U.S.A. & Mexico) Operation & Maintenance Manual

4.5.2.1 Checking the air end of a new machine

Rotate the flexible drive coupling by hand through two
complete revolutions in the direction indicated by the
arrows located on the air end and motor.
4.5.3

Checking the compressor fluid level

Open the front access panel just enough to view the sight
glass located on the separator tank, then follow the
instructions in Section 6.3.7: Compressor fluid levels on
page 34 for how to check the compressor's fluid level.
• If the fluid level is below the minimum fluid
level, see Section 6.4.1: Adding compressor
fluid on page 35.
4.5.4

Checking the isolation gate valve

If an isolation gate valve is installed in your air system,
make sure the valve is open.

4.6 Electrical checks

When performing any electrical work, refer to the electri-
cal diagram supplied with your compressor.
All the compressor's internal wiring is factory fitted and
tested. The required connection wiring is minimal, but it
must be performed by a licensed electrician. A licensed
electrician must also review the electrical system to see
that it is adequate for starting and running the compres-
sor.
4.6.1

Power supply requirements

• 460 VAC, 3-phase, 60 Hz with ground
• Control voltage: 110 VAC
88292021-240 R01
Subject to EAR, ECCN EAR99 and related export control restrictions.
4.6.2

Checking the motor rotation direction

For the motor to rotate in the correct direction, the power
supply must be correctly connected.
Never run the motor with the rotation direction
reversed!
Motor rotation in the wrong direction can dam-
age the air end and may void your warranty.
You should check the rotation of the motor before starting
up the compressor for use. Before checking the motor
rotation direction, you must familiarize yourself with Sec-
tion 5: Operation.
1. Pull out emergency stop (E-stop) button from
the monitor's control panel.
2. Press the Start button.
3. Immediately press the E-Stop button.
• This will cause the motor and air end to
rotate momentarily, but not long enough to
damage the air end if the motor rotation
direction is reversed.
• If the phase sequence is wrong, a com-
pressor with a phase sequence protector
will not start and the controller will display
an error message.
4. Check that the motor and air end rotate in
the direction indicated by the arrows on the
air end to motor drive coupling.
• If the motor and air end do not rotate in the
direction indicated by the arrows, the
incoming mains power leads need to be
reversed by a licensed electrician.
• Do not reverse any motor or starter wir-
ing. This wiring must not be modified.
4: Installation
WARNING
27

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Shoptek st55Shoptek st75

Table of Contents