ShopTek™ ST45, ST55, ST75 (U.S.A. & Mexico) Operation & Maintenance Manual
Incorrect installation or setup may void warranty.

4.1 Compressor pre-installation

Before installing your ShopTek™ compressor, check it
carefully for any transportation damage. If you find any
damage, contact your Sullair representative immediately.
4.2 Guidelines for lifting and moving
the compressor
Sullair recommends using a forklift to move the compres-
sor. A crane can also be used.
A site assessment must be carried out to ensure
forklift or crane access for removal and servicing
of major components and compressor transport.
4.2.1
Guidelines for moving the
compressor with a forklift
When using a forklift to move the compressor, follow all
local regulations for operating a forklift. In addition, Sullair
has several guidelines that must be followed.
• The forklift's load rating must be sufficient to lift
the compressor's weight (see Section 3.1:
Machine specifications on page 21)
• The forklift must lift the compressor from the
front.
• The fork tines must be correctly spaced.
• The fork lift tines must be long enough to cover
the full depth of the compressor.
• The fork tines must be fully engaged and tipped
back prior to lifting the compressor.
Section 4
Installation
WARNING
NOTE
Subject to EAR, ECCN EAR99 and related export control restrictions.
4.2.2
Guidelines for moving the
compressor with a crane
If a crane is used to move the compressor, ensure that
it's rating is sufficient to lift the compressor's weight (see
Section 3.1: Machine specifications on page 21).
When moving the compressor with a crane, lift the com-
pressor with slings and use guide ropes to prevent twist-
ing. You should also use spreader bars to prevent panel
damage.
When the compressor has been set down, check for
cracked welds and loose bolts or nuts.

4.3 Compressor installation

The ShopTek™ compressor is not weatherproof. The
compressor should be installed inside (or in a sheltered
position outside).
A site assessment must be carried out to ensure
forklift or crane access for removal and servicing
of major components and compressor transport.
4.3.1

Physical installation requirements

Because the compressor must remain level at all times
(not more than 6 mm or ¼" unevenness allowed), you
should install the compressor on a flat surface rated to
hold the compressor's weight (see Section 3.1: Machine
specifications on page 21). If you must install the com-
pressor on an uneven surface, you can use shims to
level the compressor. You do not need to bolt the com-
pressor in place.
You must position the compressor so it has sufficient
clearance on all sides (for the minimum distances
required, see the compressor's ID drawing). If you have
more than one compressor installed at the same location,
you must have clear access to each compressor. If you
need help correctly positioning your compressor, contact
your Sullair representative for assistance.
88292021-240 R01
4: Installation
NOTE
25