Make Electrical Connection - Jenn-Air KCES956KSS Installation Instructions Manual

Table of Contents

Advertisement

Available languages

Available languages

WARNING
Electrical Shock Hazard
Disconnect power before servicing.
Use 8 gauge copper wire.
Electrically ground cooktop.
Failure to follow these instructions can result in death,
fire, or electrical shock.
This cooktop is manufactured with a frame connected, green or
bare ground wire. Connect the cooktop cable to the junction box
through the UL listed or CSA approved conduit connector.
Electrical Connection Options
For cooktops with a 4-wire cable
If your home has:
And you will be
connecting to:
4-wire direct
A fused disconnect
or circuit breaker
box
5"
(12,7 cm)
3-wire direct
A fused disconnect
or circuit breaker
box
3¹⁄₂"
(8.9 cm)
For cooktops with a 3-wire cable:
If your home has:
And you will be
connecting to:
4-wire direct
A fused disconnect
or circuit breaker
box
5"
(12,7 cm)
3-wire direct
A fused disconnect
or circuit breaker
box
3¹⁄₂"
(8.9 cm)

Make Electrical Connection

IMPORTANT: Use the 4-wire cable from power supply where
local codes do not permit connecting the frame-ground
conductor to the neutral (white) junction box wire.
A. 4-wire cable from power supply
B. Black wires
C. Bare or green wires
D. 4-wire cable from cooktop
Go to Section:
E. Junction box
1. Disconnect power.
4-Wire Cable from
Power Supply to
2. Remove junction box cover, if present.
4-Wire Cable from
3. Connect the flexible cable conduit from the cooktop to the
Cooktop
4. Tighten screws on conduit connector if present.
3-Wire Cable from
5. Connect the two black wires together using the UL listed
Power Supply to
4-Wire Cable from
Cooktop
6. Connect the two red wires together using the UL listed wire
7. Connect the two white wires together using the UL listed
8. Connect the green or bare ground wire from the cooktop
Go to Section:
9. Install junction box cover.
4-Wire Cable from
Power Supply to
10. Reconnect power.
3-Wire Cable from
Cooktop
3-Wire Cable from
Power Supply to
3-Wire Cable from
Cooktop
4-Wire Cable from Power Supply to 4-Wire Cable
from Cooktop
A
B
C
D
junction box using a UL listed or CSA approved connector
for 1/2" (1.3 cm) conduit.
wire connectors.
connectors.
wire connectors.
cable to the green or bare ground wire (in the junction box)
using the UL listed wire connectors.
E
F
G
H
I
F. White wires
G. UL listed wire connector
H. Red wires
I. UL listed or CSA approved
conduit connector