Download Print this page
Jenn-Air JGD3536WS01 Installation Instructions Manual

Jenn-Air JGD3536WS01 Installation Instructions Manual

30/36" (76.2/91.4 cm) gas downdraft cooktop

Advertisement

Available languages

Available languages

Quick Links

_]ENN-AIRo
30" (76.2 CM) AND 36" (91.4 CM) GAS DOWNDRAFT
COOl(TOP INSTALLATION INSTRUCTIONS
INSTRUCTIONS D'INSTALLATION D ELATABLE DE
CUISSON A GAZ A ASPIRATION PAR LEBAS
DE 30" (76,2 CM) ETDE 36" (91,4 CM)
Table of Contents/Table des mati_res
COOKTOP SAFETY ........................................................................
1
INSTALLATION REQUIREMENTS
................................................ 3
Tools and Parts ............................................................................
3
Location Requirements ................................................................
3
Venting Requirements ..................................................................
5
Venting Methods ..........................................................................
6
Electrical Requirements ...............................................................
7
Gas Supply Requirements ...........................................................
8
INSTALLATION INSTRUCTIONS
..................................................
9
Install Cooktop .............................................................................
9
Rotate Blower - Optional ..............................................................
9
Make Gas Connection ................................................................
10
Electronic Ignition System ..........................................................
12
Complete Installation ..................................................................
12
SECURITE DE LA TABLE DE CUISSON ................................. 13
EXIGENCES D'INSTALLATION ................................................
14
Outillage et pieces ...................................................................
14
Exigences d'emplacement ......................................................
14
Exigences concernant I'evacuation ........................................ 16
Methodes d'evacuation ...........................................................
17
Specifications electriques .......................................................
19
Specifications de I'alimentation en gaz .................................. 19
INSTRUCTIONS
D'INSTALLATION
.........................................
21
Installation de la table de cuisson ........................................... 21
Rotation du ventilateur-
Facultative ....................................... 21
Raccordement au gaz .............................................................
22
Systeme d'allumage electronique ........................................... 24
Achever I'installation ...............................................................
24
COOKTOP SAFETY
Your safety and the safety of others are very important.
We have provided many important safety messages in this manual and on your appliance. Always read and obey all safety
messages.
This is the safety alert symbol.
This symbol alerts you to potential hazards that can kill or hurt you and others.
All safety messages will follow the safety alert symbol and either the word "DANGER" or "WARNING."
These words mean:
You can be killed or seriously injured if you don't immediately
follow
instructions.
You can be killed or seriously injured if you don't follow
instructions.
All safety messages will tell you what the potential hazard is, tell you how to reduce the chance of injury, and tell you what can
happen if the instructions are not followed.
iMPORTANT:
installer: Leave installation instructions with the homeowner.
Homeowner:
Keep installation instructions for future reference.
iMPORTANT
:
Installateur : Remettre les instructions d'installation au propri6taire.
Propri6taire
: Conserver les instructions d'installation pour r6f6rence ult_rieure.
W10197058A

Advertisement

loading

Summary of Contents for Jenn-Air JGD3536WS01

  • Page 1 _]ENN-AIRo 30" (76.2 CM) AND 36" (91.4 CM) GAS DOWNDRAFT COOl(TOP INSTALLATION INSTRUCTIONS INSTRUCTIONS D'INSTALLATION D ELATABLE DE CUISSON A GAZ A ASPIRATION PAR LEBAS DE 30" (76,2 CM) ETDE 36" (91,4 CM) Table of Contents/Table des mati_res SECURITE DE LA TABLE DE CUISSON ......... 13 COOKTOP SAFETY ................
  • Page 2 WARNING: If the information in this manual is not followed exactly, a fire or explosion may result causing property damage, personal injury or death. - Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance, - WHAT TO DO IF YOU SMELL GAS:...
  • Page 3 • Vent clamps Mobile Home - Additional Installation Requirements • Jenn-Air wall cap The installation of this cooktop must conform to the Jenn-Air_6 '' (15.2 cm) Round Surface Wall Cap Damper Manufactured Home Construction and Safety Standard, Title 24 Order Part Number A406...
  • Page 4 Cabinet Dimensions A. 30" (76.2 cm) F. 11H_" (4.3 cm) recommended minimum cabinet to motor B. 12 _" (32.9 cm) centerline of clearance cooktop to centerline of gas manifold pipe G. 12_" (31.8 cm) C. 4" (10.2 cm) H. 14" (35.6 cm) D.
  • Page 5 D. 53/4" (14.6 cm) on both 30" (76.2 cm) and 36" (91.4 cm) models E. 2 _" (5.4 cm) minimum space to front edge of cooktop • Use a Jenn-Air vent cap for proper performance. If an F. Floor exhaust option alternate wall or roof cap is used, be certain the cap size is G.
  • Page 6 Jenn-Air _ Duct Free Filter Accessory On select downdraft models, the Jenn-Air ® Duct Free Filter Accessory Kit Part Number JDX7000WX is now available. The Jenn-Air ® Duct Free Filter Accessory Kit is ideal for both new construction and kitchen renovation projects because it provides an easy alternative to the installation of metal ducting and venting in the downdraft system outside the home.
  • Page 7 Example vent system Calculating Vent System Length wall cap 90 ° embow To calculate the length of the system you need, add the 6 ft (1.8 m) equivalent feet (meters) for each vent piece used in the system. Vent Piece 6"...
  • Page 8 Flexible metal appliance connector: • If local codes permit, use a 1/2"or 3/4"I.D. flexible stainless steel tubing gas connector, designed by CSA to connect the cooktop to the rigid gas supply line. • A 1/2"male pipe thread is needed for connection to the Explosion Hazard female pipe threads of the inlet to the cooktop pressure regulator.
  • Page 9 Burner I nputRequirements Gas Supply Pressure Testing Input ratings shown on the model/serial rating plate are for Gas supply pressure for testing regulator must be at least elevations up to 2,000 ft (609.6 m). 1" water column pressure above the manifold pressure shown on the model/serial rating plate.
  • Page 10 3. Insert the 3/8"socket and extension into the hole and use the 4. Verify the "Top" label is positioned as shown. ratchet handle to loosen the nut half of a rotation. Repeat this process for each of the 4 nuts. 4.
  • Page 11 Typical flexible connection Complete Connection 1. Open the manual shutoff valve in the gas supply line. The valve is open when the handle is parallel to the gas pipe. A. Manifold entrance B. Gas pressure regulator C. Use pipe-joint compound. D.
  • Page 12 bysem To adjust standard burners: Initial lighting and gas flame adjustments This cooktop is equipped for electronic auto-reignition by means The flame can be adjusted using the adjustment screw in the of a spark igniter located at the rear of each burner. The burners center of the valve stem.
  • Page 13 SECURITE DE LA TABLEDECUlSSON Votre securite et celle des autres est tres importante. Nous donnons de nombreux messages de s_curit_ importants dans ce manuel et sur votre appareil m_nager. Assurez-vous toujours lire tousles messages de s_curit_ et de vous y conformer. Ce symbole d'alerte de s_curit_ vous signale les dangers potentiels de d_c_s et de blessures graves &...
  • Page 14 Clapet de bouche de decharge murale & surface de cuisson. 31¼ '' x 10" (8,3 x 25,4 cm) de Jenn-Air ® • Prevoir une ouverture dans I'angle superieur droit de Commander...
  • Page 15 Table de cuisson de 36" (91,4 cm) R6sidence mobile - Sp6cifications additionnelles respecter Iors de I'installation L'installation de cette table de cuisson doit _tre conforme aux dispositions de la norme Manufactured Home Construction Safety Standard, Title 24 CFR, Part 3280 (anciennement Federal Standard for Mobile Home Construction and Safety, Title 24,...
  • Page 16 Jenn-Air ®. Voir la section "Methodes J. 28 _" (72, 7cm) sur les modeles de 30" (76,2 cm) 343/4'' (88,3 cm) sur les modeles de 36" (91,4 cm) d'evacuation".
  • Page 17 _ travers lemur B. Conduit de dia. 6" (15,2 cm) • Utiliser un clapet de conduit Jenn-Air pour que le rendement pour sortie _ travers le toit B. Bouche de d_charge murale soit correct. Si une bouche de decharge murale ou de toit est...
  • Page 18 25,4 cm) accessoire de filtration sans conduit Jenn-Air ®, piece n° JDX7000WX est desormais disponible. La trousse accessoire de filtration sans conduit Jenn-Air ®est ideale tant pour les Bouche de decharge murale nouvelles constructions que les projets de renovation de cuisine 31/4"x 10"...
  • Page 19 IMPORTANT : La table de cuisson dolt _tre correctement reliee & la terre en conformite avec les codes et reglements Iocaux en vigueur, ou en I'absence de tels codes, avec le National Electrical Code, ANSI/NFPA 70 ou le Code canadien des installations electriques, CSA C22.1.
  • Page 20 Canalisation de gaz D_tender de gaz Le detender fourni avec cette table de cuisson doit _tre utilis& La Installer une canalisation de gaz rigide de 3A"(1,9 cm) jusqu'& I'emplacement d'installation de la table de cuisson. L'emploi pression d'alimentation du detender doit _tre comme suit pour un fonctionnement correct : d'une canalisation de plus petit diametre ou plus Iongue peut causer une deficience du debit d'alimentation.
  • Page 21 INSTRUCTIONS D'INSTALLATION Determiner I'emplacement final de la table de cuisson. IMPORTANT : Les @tapes suppl@mentaires suivantes doivent atre ex@cut@essi le produit est install@ avec une configuration d'@b@nisterie en p@ninsule ou en ilot. La volute d'@vacuation est mont@e a I'usine de mani@re ace que le syst@me d'@vacuation soit orient@ directement vers I'arri@re du Risque du poids excessif placard _ travers un mur ext@rieur.
  • Page 22 4. II est facile de faire pivoter la volute d'evacuation 4. Verifier que I'etiquette "surface superieure" est positionnee ventilateur vers le bas une fois les ecrous desserres, tel qu'illustr& 5. Resserrer chaque ecrou & I'aide de la douille de 3/8", de la rallonge et de la cle a cliquet.
  • Page 23 Achever le raccordement Raccordement typique par raccord flexible 1. Ouvrir le robinet d'arr_t manuel sur la canalisation de gaz. Le robinet est ouvert Iorsque la poignee est parallele au conduit A. Entree de la tubulure de distribution d'alimentation en gaz. B.
  • Page 24 4/09 All rights reserved. ® Registered Trademark/TM Trademark of Jenn-Air, U.S.A. Used under license by Maytag Limited in Canada. Printed in U.S.A. Tous droits reserves. ©Marque deposee/TM Marque de commerce de Jenn-Air, U.S.A. Emploi sous licence par Maytag Limited au Canada.