[Save All User Data]; [Load All User Data]; [Initialize] - Panasonic PT-RZ31К Operating Instructions Manual

Hide thumbs Also See for PT-RZ31К:
Table of Contents

Advertisement

Resetting [FILTER COUNTER]
Reset the filter runtime (counter numeric value).
1)
Press as to select [FILTER SETTING].
2)
Press the <ENTER> button.
f The [FILTER SETTING] screen is displayed.
3)
Press as to select [FILTER COUNTER RESET], and press the <ENTER> button.
4)
When the confirmation screen is displayed, press qw to select [OK], and press the <ENTER> button.
f The [PROJECTOR SETUP] menu → [STATUS] → [FILTER COUNTER] is displayed as "0".
Note
f If the recommended time to replace the filter is set, the filter runtime (counter numerical value) and the recommended time to replace the
filter are displayed in [FILTER COUNTER RESET].

[SAVE ALL USER DATA]

Save the various setting values as a backup in the built-in memory of the projector.
1)
Press as to select [SAVE ALL USER DATA].
2)
Press the <ENTER> button.
f The [SECURITY PASSWORD] screen is displayed.
3)
Enter a security password and press the <ENTER> button.
4)
When the confirmation screen is displayed, press qw to select [OK], and press the <ENTER> button.
f [PROGRESS] is displayed while saving data.
Note
f Data set from the computer application is not included in [ALL USER DATA].
f The data saved by executing [SAVE ALL USER DATA] is not deleted even if the [PROJECTOR SETUP] menu → [INITIALIZE] → [ALL
USER DATA] is executed.

[LOAD ALL USER DATA]

Load the various setting values saved as a backup in the built-in memory of the projector.
1)
Press as to select [LOAD ALL USER DATA].
2)
Press the <ENTER> button.
f The [SECURITY PASSWORD] screen is displayed.
3)
Enter a security password and press the <ENTER> button.
4)
When the confirmation screen is displayed, press qw to select [OK], and press the <ENTER> button.
Note
f The projector enters the standby mode to reflect the setting values when [LOAD ALL USER DATA] is executed.
f Data registered from a computer is not included in [ALL USER DATA].

[INITIALIZE]

Return various setting values to their factory default settings.
1)
Press as to select [INITIALIZE].
2)
Press the <ENTER> button.
f The [SECURITY PASSWORD] screen is displayed.
3)
Enter a security password and press the <ENTER> button.
f The [INITIALIZE] screen is displayed.
4)
Press as to select an item to initialize.