Panasonic KX-HGW600 Operating Instructions Manual page 95

Network camera management system
Table of Contents

Advertisement

Entry
Protocol
Forwarding Port No.
Forwarding IP
Address
Note
When Auto is displayed in the Current Status table, you cannot change the
settings because the KX-HGW600 has set up Network Camera automatically.
[For assistance, please call: 1-800-272-7033]
Instructions for the data fields
Check Enabled or Disabled. When you check Enabled, the
entry works as specified. When you check Disabled, the
entry does not work but will work when you check Enabled
later.
Select the protocol(s) to send or receive data to/from the
WAN side. TCP, UDP, TCP&UDP, ICMP or PPTP are
available.
Set the port number(s) to send or receive data to/from the
WAN side. Do not enter the space.
• When a single port is desired, set the port number.
• When a range of port is desired, enter the range using "-".
For example, to set the port numbers from 2000 to 3000,
enter as "2000-3000". The starting port number must be
lower in value than ending port number.
The port numbers from 60000 to 60016 are only available
for the KX-HGW600.
Enter the private IP address of each device connected to the
KX-HGW600. A data from the Internet is forwarded to the IP
address entered in this data field. In this case, set the IP
address of the corresponding Network Camera to this value.
Operating Instructions
95

Advertisement

Table of Contents
loading

Table of Contents