F502-EN2-04.book Seite 59 Dienstag, 26. Juli 2005 5:48 17
PNP output
Output transis-
Model
tor Status
Light ON
E3Z-T81
E3Z-T86
E3Z-T81A
E3Z-T86A
E3Z-R81
E3Z-R86
E3Z-D81
E3Z-D86
Dark ON
E3Z-D82
E3Z-D87
E3Z-L81
E3Z-L86
E3Z-B81
E3Z-B82
Through-beam emitter
E3Z-B86
E3Z-B87
E3Z-G81
Light ON
Dark ON
E3Z-LS81
E3Z-LS86
Light ON
Dark ON
Light ON
E3Z-G82
Dark ON
E3Z
Mode selec-
Timing chart
tion switch
Incident
Interrupted
Operation
ON
indicator
OFF
L ON
(orange)
ON
(LIGHT ON)
Output
transistor
OFF
Operate
Load
(Relay)
Reset
(Between blue and black)
Incident
Interrupted
Operation
ON
indicator
OFF
D ON
(orange)
ON
(DARK ON)
Output
transistor
OFF
Operate
Load
(Relay)
Reset
(Between blue and black)
Power
indicator
(orange)
Main
circuit
NEAR
FAR
Operation
ON
indicator
(orange)
OFF
L ON
Output
ON
(LIGHT ON)
transistor
OFF
ON
Load (e.g.
relay)
OFF
(Between blue and black)
NEAR
FAR
Operation
ON
indicator
(orange)
OFF
D ON
ON
Output
(DARK ON)
transistor
OFF
ON
Load (e.g.
relay)
OFF
(Between blue and black)
NEAR
FAR VERY FAR
Operation
ON
indicator
(orange)
OFF
L ON
ON
Output
(LIGHT ON)
transistor
OFF
ON
Load (e.g.
relay)
OFF
(Between blue and black)
NEAR
FAR VERY FAR
Operation
ON
indicator
(orange)
OFF
D ON
ON
Output
(DARK ON)
transistor
OFF
ON
Load (e.g.
relay)
OFF
(Between blue and black)
Incident
Interrupted
ON
Operation indicator
(orange)
L ON
OFF
(LIGHT ON)
ON
Control output
Output transistor
OFF
Operate
Load
(Relay)
Reset
(Between brown and black (white)
Incident
Interrupted
ON
Operation indicator
(orange)
OFF
D ON
ON
Control output
(DARK ON)
Output transistor
OFF
Operate
Load
(Relay)
Reset
(Between brown and black (white)
Output circuit
Through-beam receiver Retroreflective model Diffuse-reflective model
Operation
Stability
indicator
indicator
(orange)
(green)
Main
Control output
circuit
Connector Pin Arrangement
2
1
Note: Terminal 2 is not used.
Brown
1
Connector Pin Arrangement
12 to 24
VDC
Note: Terminal 2 and 4 are not used.
Blue
3
Operation
Stability
indicator
indicator
(orange)
(green)
Control
Main
output
circuit
Connector Pin Arrangement
2
4
1
BGS: Either leave the pink wire (2) open or connect it to the blue wire (3).
FGS: Connect the pink wire (2) to the brown wire (1).
Operation
indicator
Z
Operation
S 2 (orange)
indicator
S 1
(Control output)
Main
(orange)
circuit
Z
D
(Control output)
Brown
12 to 24 VDC
1
Z
D
Black
4
100 mA
Load
max.
(Relay)
Blue
3
0V
4
3
2
4
1
3
Brown
12 to 24 VDC
1
FGS
Z
D
Black
4
100 mA
max.
Pink
Load (Relay)
2
BGS
0 V
Blue
3
3
Brown
1
12 to 24 VDC
D
White
2
Load
100 mA
(Relay)
max.
Black
4
Load
100 mA
(Relay)
max.
Blue
0V
3
Connector Pin arrangement
2
4
1
3
A-59

Advertisement

loading

This manual is also suitable for:

E3z-b61 2m