Any other type of connection/application of the WiN5200 and/or WiN1010 is not allowed.
Route all power supply cords so that people cannot walk on them, or place objects on or
against them. This can pinch or damage the cords.
Servicing
Do not open the cover of this product and perform corrective actions unless instructed to do
so in the operating instructions.
Outdoor Grounding System
Verify that the antenna or cable system is grounded (earthed).
The antenna is an integral part of the CPE (Models WiN51XX)
The CPE (antenna) installation must be as per Article 810 of the NEC. Of particular note is the
requirement that the grounding conductor not be less than 10 AWG (Cu). The scheme should
be either in accordance with UL 96 and 96A. Lightning Protection Components and
Installation Requirements for Lightning Protection Systems, or tested in accordance with UL
50 and UL 497.
CAUTION
To reduce the risk of fire, use only No. 26AWG or larger telecommunication line cord
between the indoor and outdoor units.
WiN5200
Introduction | 9