Checking The Airfl Ow; System Fans; Optional Fan Confi Gurations - Supero SUPERSERVER 2027TR-HTQRF User Manual

Table of Contents

Advertisement

6-5
Checking the Airfl ow
Checking Airfl ow
1. Make sure there are no objects obstructing the airfl ow in and out of the
chassis. In addition, if you are using a front bezel, make sure the bezel's fi lter
is replaced periodically.
2. Except for brief periods while swapping hard drives, do not operate the server
without drives or the drive carriers in the drive bays. Use only recommended
server parts.
3. Make sure no wires or foreign objects obstruct airfl ow through the chassis.
Pull all excess cabling out of the airfl ow path or use shorter cables.
4. The control panel LEDs inform you of system status. See "Chapter 3: System
Interface" for details on the LEDs and the control panel buttons.
6-6

System Fans

Four fans provide cooling for the chassis. These fans circulate air through the
chassis as a means of lowering the chassis internal temperature. The SC217 system
fans are easy to change modules. There is no need to uninstall any other parts
inside the system when replacing fans, and no tools are required for installation.
Optional Fan Confi gurations
The SC217H model chassis is designed so that the default confi guration of the
system is for each motherboard to control two fans. Each motherboard node in
the chassis is connected to the backplane through the adapter card, mounted in
the motherboard node drawer. In the event that one of the motherboard drawers is
removed, then the remaining motherboard will operate both fans.
Fan Confi gurations Options
SC217H Hot-Swappable Default Confi guration
Fans A and B connected to backplane,
backplane connected to Node A and B by adapter card
Fans C and D connected to backplane,
backplane connected to Nodes A and B by adapter card
6-5
Chapter 6: Advanced Chassis Setup