SUPERSERVER 2027TR-HTQRF/HTFRF/HTRF User's Manual
Chassis
SC217HQ-R1620B (2U rackmount)
Dimensions: (WxHxD) 17.25 x 3.47 x 28.5 in. (438 x 88 x 724 mm)
Weight
Gross (Bare Bone): 85 lbs. (38.6 kg.)
System Cooling
The system has four (4) 8-cm PWM system cooling fans
System Input Requirements
AC Input Voltage: 85-264V AC auto-range
Rated Input Current: 15 - 5A
Rated Input Frequency: 47 to 63 Hz
Effi ciency: 90+ (Platinum Level)
Power Supply
Rated Output Power: 1620 Watts (Part# PWS-1K62P-1R)
Rated Output Voltages: +12V (135A@180-264V, 100A@120-140V), +5Vsb (6A)
Operating Environment
Operating Temperature: 0º to 35º C (50º to 95º F)
Non-operating Temperature: -40º to 70º C (-40º to 158º F)
Operating Relative Humidity: 20% to 95% (non-condensing)
Non-operating Relative Humidity: 5 to 95% (non-condensing)
Regulatory Compliance
Electromagnetic Emissions: FCC Class A, EN 55022 Class A, EN 61000-3-2/-3-
3, CISPR 22 Class A
Electromagnetic Immunity: EN 55024/CISPR 24, (EN 61000-4-2, EN 61000-4-3,
EN 61000-4-4, EN 61000-4-5, EN 61000-4-6, EN 61000-4-8, EN 61000-4-11)
Safety: CSA/EN/IEC/UL 60950-1 Compliant, UL or CSA Listed (USA and
Canada), CE Marking (Europe)
California Best Management Practices Regulations for Perchlorate Materials:
This Perchlorate warning applies only to products containing CR (Manganese
Dioxide) Lithium coin cells. "Perchlorate Material-special handling may apply.
See www.dtsc.ca.gov/hazardouswaste/perchlorate" for further details.