Other risks
Additional residual risks may arise when using the tool
which may not be included in the enclosed safety warnings.
These risks can arise from misuse, prolonged use etc. In
spite of the application of the relevant safety regulations and
the implementation of safety devices, certain risks cannot be
avoided. These are:
•
Injuries caused by touching any rotating/moving parts.
•
Injuries caused when changing any parts, blades or
accessories.
•
Injuries caused by prolonged use of a tool. When using
any tool for prolonged periods ensure you take regular
breaks.
•
Impairment of hearing.
•
Health hazards caused by breathing dust developed
when using your tool (example:- working with wood,
especially oak, beech and MDF.)
Labels on tool
The label on your tool may include the following symbols:
Hz ....... Hertz
Read
Instructions
W ........ Watts
Manual
min ..... minutes
Use Eye
Protection
..... Alternating
Use Ear
Protection
..... Direct
V ........ Volts
n
....... No-Load
0
A ........ Amperes
Position of date barcode (Fig.C)
The Date Code(12), which also includes the year of
manufacture, is printed into the housing.
Example:
2014 XX JN
Year of manufacturing
Electrical Safety
Your tool is double insulated; therefore no earth
wire is required. Be sure to check that the power
supply corresponds to the voltage on the rating plate.
Corresponds.
...... Class II
Construction
....
Earthing
Terminal
....
Safety Alert
Current
Symbol
.../min..
Revolutions
Current
or Recipro-
cation per
minute
Speed
(Original instructions)
•
If the supply cord is damaged, it must be replaced by the
manufacturer or an authorised STANLEY Service Centre
in order to avoid a hazard.
Using an Extension Cable
If it is necessary to use an extension cable, please used an
approvedextension cable that fits the tool's power input
specifications (please refer to the technical data). The
minimum crosssectional area of the conducting wire is 1.5
sq. mm. Cables should be untangled before reeling up.
Please refer to the following table.
Cable cross-sectional area (mm
0.75
1.00
1.50
2.50
4.00
o V
a t l
e g
m A
e p
s e r
115
0 - 2.0
2.1 - 3.4
3.5 - 5.0
5.1 - 7.0
7.1 - 12.0
12.1 - 20.0
230
0 - 2.0
2.1 - 3.4
3.5 - 5.0
5.1 - 7.0
7.1 - 12.0
12.1 - 20.0
ENGLISH
2
)
Cable rated current (Ampere)
6
10
15
20
25
Cable length (m)
7.5 15 25 30 45
60
a C
e l b
a r
d e t
u c
e r r
( t n
m A
e p
6
6 6 6 6 10
6
6 6 6 15 15
6
6 10 15 20 20
10 10 15 20 20 25
15 15 20 25 25 -
20 20 25 - - -
6 6 6 6 6 6
6
6 6 6 6 6
6
6 6 6 10 15
10 10 10 10 15 15
15 15 15 15 20 20
20 20 20 20 25 -
) e r
5