Humidity Control Adjustment; Setpoint Adjustment - Trane BAYSTAT253A Installer's Manual

Humidity control

Advertisement

BAYSTAT253A HUMIDITY CONTROL
HEATING CYCLE HUMIDITY
CONTROL ADJUSTMENTS

Humidity Control Adjustment

To maintain optimum humidity control without causing
condensation on cold surfaces such as windows, the
homeowner must adjust the setpoint as the outdoor
temperature changes.
To reduce relative humidity, reduce the setpoint
approximately 3% RH humidity every 24 hours. To
increase relative humidity, increase the setpoint
approximately 3% RH every 24 hours.
Pub.No.: 22-5203-01
69-1698

Setpoint Adjustment

Set the humidity setpoint according to the prevailing
outdoor temperature. See Table 1 for recommended
settings.
Table 1. Recommended Humidity Control Setting.
Outdoor Temperature
°F
-20
-10
0
+10
+20
>+20
4
Recommended
Humidity Control
°C
Setting
-29
15
-23
20
-18
25
-12
30
-7
35
>-7
40