12. Installation Instruction

12.1 Select The Best Location

12.1.1
Indoor Unit
Do not install the unit in excessive oil fume area
such as kitchen, workshop and etc.
There should not be any heat source or steam
near the unit.
There should not be any obstacles blocking the air
circulation.
A place where air circulation in the room is good.
A place where drainage can be easily done.
A place where noise prevention is taken into
consideration.
Do not install the unit near the door way.
Ensure the spaces indicated by arrows from the
wall, ceiling, fence or other obstacles.
Recommended installation height for indoor unit
shall be at least 2.5 m.
12.1.2
Outdoor Unit
If an awning is built over the unit to prevent direct
sunlight or rain, be careful that heat radiation from
the condenser is not obstructed.
There should not be any animal or plant which
could be affected by hot air discharged.
Keep the spaces indicated by arrows from wall,
ceiling, fence or other obstacles.
Do not place any obstacles which may cause a
short circuit of the discharged air.
If piping length is over the [piping length for
additional gas], additional refrigerant should be
added as shown in the table.
Piping size
Horse
Model
Power
(HP)
Gas
Liquid
HZ9***,
1.0HP 9.52mm
6.35mm
AZ9***
(3/8")
(1/4")
HZ12***
1
5 .
H
P
Example: For HZ9***
If the unit is installed at 10 m distance, the quantity of
additional refrigerant should be 50 g .... (10-7.5) m ×
20 g/m =50 g.
Min.
Max.
Std.
Max.
Additional
Piping
Piping
Length
Elevation
Refrigerant
Length
Length
(m)
(m)
(g/m)
(m)
(m)
10
3
20
20
5
10
3
20
0 2
12.1.3
50 mm
or more
Insulation of piping connections
Carry out insulation after
checking for gas leaks and
secure with vinyl tape.
Attaching the remote control holder to the wall
Remote control holder fixing screws
Remote
control
3
Piping
Length
for add.
gas (m)
7.5
This illustration is for explanation purposes only.
7
5 .
The indoor unit will actually
face a different way.
30
Indoor/Outdoor Unit Installation
Diagram
Piping direction
Attention not to bend
(Front side)
up drain hose
Right
Right
Rear
Left
Right
bottom
(Left and right are identical)
Vinyl tape
6
Remote control holder
5
It is advisable to
avoid more than 2
blockage directions.
For better ventilation
& multiple-outdoor
installation, please
consult authorized
dealer/specialist.
This illustration is for
explanation purposes only.
The indoor unit will actually face a different way.
WARNING
Flare connection
only at outside
of building
Installation parts you
( )
should purchase
Installation plate 1
( )
Bushing-Sleeve
( )
Sleeve
( )
Putty
(Gum Type Sealer)
Bend the pipe as
closely on the wall as
possible, but be careful
that it doesn't break.
In case of indoor power supply
( )
Power supply cord
Flare connection
only at outside
of building
Vinyl tape (wide)
( )
Apply after carrying
out a drainage test.
To carry out the
drainage test,
remove the air fi lters
and pour water into
the heat exchanger.
( )
Saddle
In case of outdoor power supply
( )
Power supply cord
Connection cable
( )
Liquid side piping
( )
Gas side piping
( )
Additional drain hose
Control Board cover