Panasonic CS-HZ12RKE Service Manual page 106

Hide thumbs Also See for CS-HZ12RKE:
Table of Contents

Advertisement

17.4.22
F91 (Refrigeration Cycle Abnormality)
Malfunction Decision Conditions
The input current is low while the compressor is running at higher than the setting frequency.
Malfunction Caused
Lack of gas.
3-way valve close.
Troubleshooting
When F91 indication happens
Check 3 way valve
3-way valve opened?
Check for gas leaking source (Refer to H16)
Gas leaking?
Check other parts in refrigeration cycles
YES
NO, gas amount is OK
Caution
NO, closed
YES
106
For safety reason and to prevent
component breakdown, always switch
off the power before remove and
connect the component.
Open 3 way valve
Check for gas leaking source;
Repair or replace defected part(s)
Re-claim and then re-charge the
right amount

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents