Download Print this page

Singer XL-420 Service Manual page 18

Hide thumbs Also See for XL-420:

Advertisement

Service Manual
SEC.5-4
Presser foot height and direction (4)
Adjustment-3
 When the presser foot and ditch of feed dog on the needle plate is not equally
balanced to left and right direction
1. Loosen 3 screws at F, G and H at rear part of board (E).
2. Shake the board (E) to left and right around screw (F) and adjust presser foot to
balanced position as shown on below picture.
Shift the presser foot to the arrow as shown on above pictures to make
adjustment. Note: The presser foot shown in this picture is not for FQ-4
3. Tighten screw (B) properly after adjustment.
E
H
Model
F
G
Original issue
May 2014
Page 18/64
XL-420
| 18

Advertisement