INSTALLATION
LOCATING YOUR
GAS FIREPLACE
1) When selecting a location for your stove,
ensure that the clearances are met as
outlined in the "Clearances" section.
2) Provide adequate clearances for servicing.
3) The appliance must be installed on a flat,
solid, continuous surface (e.g. wood, metal,
concrete). This may be the floor, or raised up
on a platform to enhance its visual impact.
If the appliance is going to be installed
on carpeting, combustible linoleum tile or
other combustible material other than wood
flooring, the appliance must be installed on
a metal or wood panel extending the full
width and depth of the appliance.
4) The Room Sealed Gas Fireplace can be
installed as follows:
Model #
Position
A)
PG121-1: See Thru
B)
PG131-1: Pier
C)
PG121LC-1: Left Corner
D)
PG121RC-1: Right Corner
5) This appliance is Listed for bedroom instal-
lations when used with a Listed Millivolt
Thermostat. Some areas may have further
requirements, check local codes before
installation.
6) The PG121-1 / PG121LC-1 / PG121RC-1
/ PG131-1 Room Sealed Gas Fireplace is
approved for alcove installations, which
meet the clearances listed on this page.
7) We recommend that you plan your instal-
lation on paper using exact measurements
for clearances and floor protection before
actually installing this appliance. Have a
authorized inspector, dealer, or installer
review your plans before installation.
Note: For Exterior Flue Termination
Locations see"Exterior Flue Termina-
tion" section.
.
8
A) PG121-1 - See Thru
B) PG131-1 - Pier
C) PG121LC-1 - Left Corner
D) PG121RC-1 - Right Corner
Regency PG121/PG131 Zero Clearance Room Sealed Gas Fireplace