HCD-CPX22/NXM3
NOTES ON HANDLING THE OPTICAL PICK-UP BLOCK
OR BASE UNIT
The laser diode in the optical pick-up block may suffer electrostatic
break-down because of the potential difference generated by the
charged electrostatic load, etc. on clothing and the human body.
During repair, pay attention to electrostatic break-down and also
use the procedure in the printed matter which is included in the
repair parts.
The flexible board is easily damaged and should be handled with
care.
NOTES ON LASER DIODE EMISSION CHECK
The laser beam on this model is concentrated so as to be focused on
the disc reflective surface by the objective lens in the optical pick-
up block. Therefore, when checking the laser diode emission, observe
from more than 30 cm away from the objective lens.
LASER DIODE AND FOCUS SEARCH OPERATION CHECK
Carry out the "S curve check" in "CD section adjustment" and check
that the S curve waveform is output several times.
• Abbreviation
E3
E51 : Chilean and Peruvian model
EA
RU : Russian model
• SERVICE POSITION FOR TAPE MECHANISM DECK
4
SECTION 1

SERVICING NOTES

: 240 V AC Area in E model
: Saudi Arabia model
CN301
Jig (J-2501-270-A)
CN302
• MODEL IDENTIFICATION
– Back Panel –
MODEL
AEP, UK models
RU model
E3 model
E51 model
US model
EA model
Jig (J-2501-271-A)
tape mechanism deck
PART No.
PART No.
4-253-358-0[]
4-253-358-1[]
4-253-358-2[]
4-253-358-3[]
4-253-358-4[]
4-253-358-5[]