FORM 150.73-NM1
ISSUE DATE: 09/04/2020
TABLE 40 – ISN TRANSMITTED DATA (CONT'D)
ISN
CHARACTER
TYPE
PAGE
P37
109
Digital
P38
110
Digital
P39
111
Digital
P40
112
Digital
P41
113
Digital
P42
114
Digital
P43
115
Digital
P44
116
Digital
P45
117
Digital
P46
118
Digital
P47
119
Digital
P48
120
Digital
P49
121
Digital
P50
122
Digital
P51
123
Digital
P52
124
Digital
P53
125
Digital
P54
126
Digital
P55
127
Digital
P56
128
Coded
P57
129
Coded
P58
130
Coded
P59
131
Coded
* The operational and fault codes sent to ISN pages 56 through 59 are defined in Table 42. Note that this table of fault and operational codes
is for all DX products.
JOHNSON CONTROLS
DATA
SYS 2 Alarm
Evaporator Heater
Status
Evaporator Pump
Status
SYS 1 Comp. 2 Run
SYS 2 Comp. 2 Run
SYS 1 Liquid Line
Solenoid Valve or EEV
Pilot Solenoid
SYS 1 Hot Gas
Bypass Valve
SYS 1 Comp. 2 Run
SYS 2 Comp. 2 Run
SYS 2 Liquid Line
Solenoid Valve or EEV
Pilot Solenoid
Lead System
(0=SYS 1,
1=SYS 2)
SYS 1 Comp.3 Run
SYS 2 Comp. 3 Run
Chilled Liquid Type
(0=Water, 1=Glycol)
Ambient Control Mode
(0=Std. Ambient,
1=Low Ambient)
Local/Remote
Control Mode
(0=Local,
1=Remote)
Units
(0=Imperial, 1= SI)
Lead/Lag Control
Mode
(0=Manual,1= Remote)
----
* SYS 1
Operational Code
* SYS 1
Fault Code
* SYS 2
Operational Code
* SYS 2
Fault Code
TABLE 40 – ISN TRANSMITTED DATA (CONT'D)
ISN
CHARACTER
TYPE
PAGE
P60
132
Coded
P61
133
Coded
P62
134
Coded
P63
135
Coded
P64
136
Coded
P65
137
Coded
P66
138-141
Analog
P67
142-145
Analog
P68
146-149
Analog
P69
150-153
Analog
P70
154-157
Analog
P71
158-161
Analog
P72
162-165
Analog
P73
166-169
Analog
P74
170-173
Analog
P75
174-177
Analog
P76
Analog
178-181
P77
182-185
Analog
P78
186-189
Analog
P79
190-193
Analog
P80
194
Digital
P81
195
Digital
P82
196
Digital
P83
197
Digital
P84
198
Digital
SECTION 10 – MAINTENANCE
DATA
----
SYS 1 Condenser
Fan Stage
----
SYS 2 Condenser
Fan Stage
----
Unit Control Mode
(0=Leaving Water,
1=Return Water,
2=Discharge Air,
3=Suction Press.,
4=Cooling
5=Heating)
Anti-Recycle Timer
Leaving Chilled Liquid
Temp. Cutout
Low Ambient
Temp. Cutout
----
Low Suction
Pressure Cutout
High Discharge
Pressure Cutout
Setpoint
Cooling Range
----
----
SYS 1 Discharge
Temp.
(EEV Only-Optional)
SYS 1 Discharge
Superheat
(EEV Only- Optional)
SYS 2 Discharge
Temp.
(EEV Only- Optional)
SYS 2 Discharge
Superheat
(EEV Only- Optional)
----
----
----
----
----
155
10